440 W, 96 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
440W / 418.7W
Efficiency
22.8%
Voc / Vmp
35.47V / 29.42V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SEG Solar |
|---|---|
| Model Number (MPN) | SEG-440-BTE-BG |
| Cell Technology | Mono-c-Si (Bifacial) · 96 cells |
| Nameplate Power (Pmax STC) | 440 W |
| Real-World Output (PTC) | 418.7 W (95.2% of STC) |
| Module Efficiency | 22.8% (228 W/m²) |
| Open-Circuit Voltage (Voc) | 35.47 V |
| Maximum Power Voltage (Vmp) | 29.42 V |
| Short-Circuit Current (Isc) | 15.77 A (NEC 1.25× = 19.71 A) |
| Maximum Power Current (Imp) | 14.96 A |
| Temp. Coeff. Power (γPmax) | -0.29 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.237 %/°C |
| Temp. Coeff. Current (αIsc) | +0.055 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.93 m² (20.8 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.237%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 35.47 V | 16 | 28 |
| 0°C / 32°F Freezing / Mild Winter | 37.57 V | 15 | 26 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 38.41 V | 15 | 26 |
| -20°C / -4°F Northeast / Midwest Winter | 39.25 V | 15 | 25 |
| -30°C / -22°F Northern Plains / Mountain | 40.09 V | 14 | 24 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 14 panels | 6.16 kW | 291 sq ft (27.0 m²) |
| 8 kW | 19 panels | 8.36 kW | 395 sq ft (36.7 m²) |
| 10 kW | 23 panels | 10.12 kW | 478 sq ft (44.4 m²) |
| 12 kW | 28 panels | 12.32 kW | 582 sq ft (54.0 m²) |
Compatible CEC-Listed Inverters for SEG-440-BTE-BG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 3–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7PLUS-72-2-US | Microinverter | 0.29 kW | 97% | 1:1 micro pairing (1.52 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC5.0-1U-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW5000-SBP-US20 | Hybrid | 4.983 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This SEG Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SEG-445-BTE-BG | 445 W | 423.6 W | 35.64 V | 15.83 A | 23.06% |
| SEG-450-BTE-BG | 450 W | 428.5 W | 35.82 V | 15.9 A | 23.32% |
| SEG-455-BTE-BG | 455 W | 433.3 W | 36 V | 15.96 A | 23.58% |
| SEG-460-BTE-BG | 460 W | 438.2 W | 36.2 V | 16.03 A | 23.83% |
| SEG-465-BTE-BG | 465 W | 443.1 W | 36.4 V | 16.09 A | 24.09% |
Engineering FAQ — SEG Solar SEG-440-BTE-BG
How many SEG Solar SEG-440-BTE-BG panels can fit in one 600V string?
At -10°C (14°F) ambient, the SEG-440-BTE-BG open-circuit voltage rises from 35.47V to 38.41V (using βVoc -0.237%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SEG Solar SEG-440-BTE-BG?
Rated at 440W STC, the SEG-440-BTE-BG carries a 418.7W PTC rating (95.2% PTC/STC ratio) and 22.8% module efficiency across 1.93 m² (20.8 sq ft).
Is the SEG Solar SEG-440-BTE-BG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.