Enphase Energy official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Enphase Energy IQ7-60-E-ACM-US-NM (0.24 kW)

240 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.24 kW
CEC Weighted Eff.
97%
MPPT / Max DC
27–37V / 37V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Enphase Energy IQ7-60-E-ACM-US-NM — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–37 Vdc 27V 37V MAX 37V PV DC INPUT ≤ 37V DC 0.24 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy IQ7-60-E-ACM-US-NM Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)IQ7-60-E-ACM-US-NM
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.24 kW (240 W)
Nominal DC Input (Pdco)247 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window27 – 37 Vdc (NREL SAM Measured)
Max DC Input Voltage37 Vdc
Max DC Input Current7.7 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryUL
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IQ7-60-E-ACM-US-NM
Max Continuous AC Current1 A @ 240V
125% Continuous Duty Current1.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.26–0.32 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IQ7-60-E-ACM-US-NM
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.67× DC/AC)
440W1 panel1:1 pairing (1.83× DC/AC)
550W1 panel1:1 pairing (2.29× DC/AC)

Compatible Solar Panels for Enphase Energy IQ7-60-E-ACM-US-NM

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Enphase Energy IQ7-60-E-ACM-US-NM
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
REC Solar REC380AA Black380 W44.3 VDC/AC 1.58 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO BLK ML-G10+ 380380 W45.16 VDC/AC 1.58 (1 panel/input)Verify Pair

Engineering FAQ — Enphase Energy IQ7-60-E-ACM-US-NM

What size circuit breaker does the Enphase Energy IQ7-60-E-ACM-US-NM require under NEC 705.12?
At 0.24 kW continuous AC output on 240V (1A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ7-60-E-ACM-US-NM?
As a 240W microinverter, it pairs 1:1 with panels rated roughly 252W to 348W STC.

More Enphase Energy Inverters

S230-60-LL-x (0.22 kW)IQ6-60-2-US (0.23 kW)IQ7-60-2-US (0.24 kW)IQ6PLUS-ACB-LL (0.27 kW)S280-60-LL-x (0.27 kW)IQ6PLUS-72-2-US (0.28 kW)All Enphase Energy Equipment →