Enphase Energy official logoCEC-Listed · Commercial / C&IMicroinverter

Enphase Energy IQ8D-72-E-US (0.64 kW)

633 VA, 208 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.64 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
60–95V / 95V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Enphase Energy IQ8D-72-E-US — Real Enphase rooftop microinverter hardware
Real Enphase rooftop microinverter hardwareWikimedia Commons — File:Enphase M190.jpg (CC BY-SA 3.0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 60–95 Vdc 60V 95V MAX 95V PV DC INPUT ≤ 95V DC 0.64 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 208V · 15A BRKR

Electrical & Grid-Support Datasheet

Enphase Energy IQ8D-72-E-US Electrical and Grid-Support Specifications
ManufacturerEnphase Energy
Model Number (MPN)IQ8D-72-E-US
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.64 kW (640 W)
Nominal DC Input (Pdco)659 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window60 – 95 Vdc (NREL SAM Measured)
Max DC Input Voltage95 Vdc
Max DC Input Current8.5 A
Night Tare Loss0.04 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for IQ8D-72-E-US
Max Continuous AC Current1.8 A @ 208V
125% Continuous Duty Current2.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.7–0.86 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for IQ8D-72-E-US
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.63× DC/AC)
440W1 panel1:1 pairing (0.69× DC/AC)
550W1 panel1:1 pairing (0.86× DC/AC)

CEC-Listed 240V Equivalents to Enphase Energy IQ8D-72-E-US

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.64 kW Microinverter) and can be added directly to your US System Kit:

CEC-Listed · 240V0.639 kW
NEP (Northern Electric & Power) · Microinverter

BDM-650

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.642 kW
Hoymiles · Microinverter

HMS-700-2T-NA

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.656 kW
APsystems · Microinverter

DS3-S

CEC Efficiency: 96.5%
Datasheet →

Compatible Solar Panels for Enphase Energy IQ8D-72-E-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Enphase Energy IQ8D-72-E-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 0.91 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 0.91 (1 panel/input)Verify Pair

Engineering FAQ — Enphase Energy IQ8D-72-E-US

What size circuit breaker does the Enphase Energy IQ8D-72-E-US require under NEC 705.12?
At 0.64 kW continuous AC output on 208V (1.8A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Enphase Energy IQ8D-72-E-US?
As a 640W microinverter, it pairs 1:1 with panels rated roughly 672W to 928W STC.

More Enphase Energy Inverters

IQ9N-A-DOM-US-HPB (0.44 kW)IQ8P-72-2-US (0.475 kW)IQ8D-BAT (0.639 kW)IQ7PD-72-2-US (0.19 kW)IQ7PD-84-2-US (0.21 kW)S230-60-LL-x (0.22 kW)All Enphase Energy Equipment →