APsystems official logoCEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

APsystems DS3-S (0.656 kW)

640 VA, 240 Vac Grid Support Utility Interactive Microinverter, Rack mounted. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.656 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
36–43V / 43V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
APsystems DS3-S — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 36–43 Vdc 36V 43V MAX 43V PV DC INPUT ≤ 43V DC 0.656 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

APsystems DS3-S Electrical and Grid-Support Specifications
ManufacturerAPsystems
Model Number (MPN)DS3-S
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.656 kW (656 W)
Nominal DC Input (Pdco)675 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window36 – 43 Vdc (NREL SAM Measured)
Max DC Input Voltage43 Vdc
Max DC Input Current17.3 A
Night Tare Loss0.03 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for DS3-S
Max Continuous AC Current2.7 A @ 240V
125% Continuous Duty Current3.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.72–0.89 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for DS3-S
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.61× DC/AC)
440W1 panel1:1 pairing (0.67× DC/AC)
550W1 panel1:1 pairing (0.84× DC/AC)

Engineering FAQ — APsystems DS3-S

What size circuit breaker does the APsystems DS3-S require under NEC 705.12?
At 0.656 kW continuous AC output on 240V (2.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the APsystems DS3-S?
As a 656W microinverter, it pairs 1:1 with panels rated roughly 689W to 951W STC.

More APsystems Inverters

ELS-9.6 (9.606 kW)ELS-11.4 (11.415 kW)YC600 (0.55 kW)DS3-L (0.78 kW)DS3 (0.896 kW)DS3-H (1.068 kW)All APsystems Equipment →