FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet

Fortress Power EdgeOn Duo 15 (10.14 kW)

10 kW, 240 Vac Grid Support Hybrid Utility Interactive with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
10.14 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power EdgeOn Duo 15 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 10.14 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Fortress Power EdgeOn Duo 15 Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)EdgeOn Duo 15
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)10.14 kW (10,140 W)
Nominal DC Input (Pdco)10,507 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage600 Vdc
Max DC Input Current32.4 A
Night Tare Loss16.94 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for EdgeOn Duo 15
Max Continuous AC Current42.2 A @ 240V
125% Continuous Duty Current52.8 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (11.15–13.69 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for EdgeOn Duo 15
Panel ClassRecommended QtyDC Array / Ratio
400W28–34 panels11.2–13.6 kW DC
440W25–31 panels11.0–13.6 kW DC
550W20–25 panels11.0–13.8 kW DC

Compatible Solar Panels for Fortress Power EdgeOn Duo 15

Test any of 3,007 panels with this inverter →
Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
Compatible Solar Panels for Fortress Power EdgeOn Duo 15
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power EdgeOn Duo 15

What size circuit breaker does the Fortress Power EdgeOn Duo 15 require under NEC 705.12?
At 10.14 kW continuous AC output on 240V (42.2A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fortress Power EdgeOn Duo 15?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 10.14 kW unit with 11.15 kW to 13.69 kW DC of solar modules without exceeding 600V cold Voc.

More Fortress Power Inverters

EdgeOn Duo 12 (8.047 kW)FP-ENVY-10K (9.759 kW)Avalon HV PC100 (10.001 kW)EdgeOn Duo 15 Lite (10.147 kW)Avalon HV PC114 (11.406 kW)EdgeOn Duo 15 Pro (11.567 kW)All Fortress Power Equipment →