FP CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Fortress Power Avalon HV PC114 (11.406 kW)

11.4 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.406 kW
CEC Weighted Eff.
97%
MPPT / Max DC
245–450V / 450V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fortress Power Avalon HV PC114 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 245–450 Vdc 245V 450V MAX 450V PV DC INPUT ≤ 450V DC 11.406 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

Fortress Power Avalon HV PC114 Electrical and Grid-Support Specifications
ManufacturerFortress Power
Model Number (MPN)Avalon HV PC114
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.406 kW (11,406 W)
Nominal DC Input (Pdco)11,710 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window245 – 450 Vdc (NREL SAM Measured)
Max DC Input Voltage450 Vdc
Max DC Input Current30.8 A
Night Tare Loss15.36 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Avalon HV PC114
Max Continuous AC Current47.5 A @ 240V
125% Continuous Duty Current59.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.55–15.4 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Avalon HV PC114
Panel ClassRecommended QtyDC Array / Ratio
400W31–39 panels12.4–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for Fortress Power Avalon HV PC114

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fortress Power Avalon HV PC114
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Fortress Power Avalon HV PC114

What size circuit breaker does the Fortress Power Avalon HV PC114 require under NEC 705.12?
At 11.406 kW continuous AC output on 240V (47.5A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fortress Power Avalon HV PC114?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.406 kW unit with 12.55 kW to 15.4 kW DC of solar modules without exceeding 450V cold Voc.

More Fortress Power Inverters

Avalon HV PC100 (10.001 kW)EdgeOn Duo 15 (10.14 kW)EdgeOn Duo 15 Lite (10.147 kW)EdgeOn Duo 15 Pro (11.567 kW)FP-ENVY-12K (11.933 kW)FP-Envy 15K (16.153 kW)All Fortress Power Equipment →