FX CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

FoxESS H1-11.4-US (11.512 kW)

11.4 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.512 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
305–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
FoxESS H1-11.4-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 305–480 Vdc 305V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.512 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

FoxESS H1-11.4-US Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)H1-11.4-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.512 kW (11,512 W)
Nominal DC Input (Pdco)11,849 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window305 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current31.2 A
Night Tare Loss27.23 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for H1-11.4-US
Max Continuous AC Current48 A @ 240V
125% Continuous Duty Current60.0 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.66–15.54 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for H1-11.4-US
Panel ClassRecommended QtyDC Array / Ratio
400W32–39 panels12.8–15.6 kW DC
440W29–35 panels12.8–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Compatible Solar Panels for FoxESS H1-11.4-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for FoxESS H1-11.4-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-560-BTC-HV560 W48.81 V9–9 per string (-10°C)Verify Pair
Canadian Solar CS6W-520MB-AG520 W48.4 V9–9 per string (-10°C)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 V11–11 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V12–12 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 V11–11 per string (-10°C)Verify Pair

Engineering FAQ — FoxESS H1-11.4-US

What size circuit breaker does the FoxESS H1-11.4-US require under NEC 705.12?
At 11.512 kW continuous AC output on 240V (48A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the FoxESS H1-11.4-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.512 kW unit with 12.66 kW to 15.54 kW DC of solar modules without exceeding 480V cold Voc.

More FoxESS Inverters

AIO-AC1-11.4-US (11.339 kW)AIO-H1-11.4-US (11.361 kW)AC1-11.4-US (11.44 kW)M1-800-NA (0.814 kW)M1-1000-NA (1.005 kW)M1-1200-NA (1.201 kW)All FoxESS Equipment →