FX CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

FoxESS M1-1200-NA (1.201 kW)

1200 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.201 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
FoxESS M1-1200-NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–50 Vdc 35V 50V MAX 50V PV DC INPUT ≤ 50V DC 1.201 kW · 95.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

FoxESS M1-1200-NA Electrical and Grid-Support Specifications
ManufacturerFoxESS
Model Number (MPN)M1-1200-NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.201 kW (1,201 W)
Nominal DC Input (Pdco)1,264 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency95.5%
MPPT Operating Window35 – 50 Vdc (NREL SAM Measured)
Max DC Input Voltage50 Vdc
Max DC Input Current30.1 A
Night Tare Loss0.42 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for M1-1200-NA
Max Continuous AC Current5 A @ 240V
125% Continuous Duty Current6.3 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.32–1.62 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for M1-1200-NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.33× DC/AC)
440W1 panel1:1 pairing (0.37× DC/AC)
550W1 panel1:1 pairing (0.46× DC/AC)

Engineering FAQ — FoxESS M1-1200-NA

What size circuit breaker does the FoxESS M1-1200-NA require under NEC 705.12?
At 1.201 kW continuous AC output on 240V (5A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the FoxESS M1-1200-NA?
As a 1201W microinverter, it pairs 1:1 with panels rated roughly 1261W to 1741W STC.

More FoxESS Inverters

H1-11.4-US (11.512 kW)M1-800-NA (0.814 kW)M1-1000-NA (1.005 kW)H1-3.8-US (3.713 kW)AC1-3.8-US (3.738 kW)AIO-AC1-3.8-US (3.782 kW)All FoxESS Equipment →