FoxESS M1-800-NA (0.814 kW)
800 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.814 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
35–50V / 50V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | FoxESS |
|---|---|
| Model Number (MPN) | M1-800-NA |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.814 kW (814 W) |
| Nominal DC Input (Pdco) | 853 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 95.5% |
| MPPT Operating Window | 35 – 50 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 50 Vdc |
| Max DC Input Current | 20.3 A |
| Night Tare Loss | 0.42 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3.4 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 4.3 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.9–1.1 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.49× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.54× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.68× DC/AC) |
Engineering FAQ — FoxESS M1-800-NA
What size circuit breaker does the FoxESS M1-800-NA require under NEC 705.12?
At 0.814 kW continuous AC output on 240V (3.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the FoxESS M1-800-NA?
As a 814W microinverter, it pairs 1:1 with panels rated roughly 855W to 1180W STC.