Gamesa Electric PV4100 (4054.978 kW)
4100 kVA, 600 Vac Grid Support Utilitity Interactive Inverters. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4054.978 kW
CEC Weighted Eff.
98%
MPPT / Max DC
835–1300V / 1300V
NEC 705.12 Breaker
4900A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Gamesa Electric |
|---|---|
| Model Number (MPN) | PV4100 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 4054.978 kW (4,054,978 W) |
| Nominal DC Input (Pdco) | 4,123,360 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 835 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 3927 A |
| Night Tare Loss | 267 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3902 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 4877.5 A |
| Minimum Standard Breaker | 4900 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (4460.48–5474.22 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 11151–13686 panels | 4460.4–5474.4 kW DC |
| 440W | 10137–12441 panels | 4460.3–5474.0 kW DC |
| 550W | 8110–9953 panels | 4460.5–5474.1 kW DC |
CEC-Listed 240V Equivalents to Gamesa Electric PV4100
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4054.978 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Gamesa Electric PV4100
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 22–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 23–23 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 22–22 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 23–23 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-550MB-AG | 550 W | 49.6 V | 24–24 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 18–18 per string (-10°C) | Verify Pair |
Engineering FAQ — Gamesa Electric PV4100
What size circuit breaker does the Gamesa Electric PV4100 require under NEC 705.12?
At 4054.978 kW continuous AC output on 600V (3902A continuous), the 125% continuous duty rule requires a minimum 4900A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Gamesa Electric PV4100?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4054.978 kW unit with 4460.48 kW to 5474.22 kW DC of solar modules without exceeding 1300V cold Voc.