Gamesa Electric PV4700 (4654.418 kW)
4700 kVA, 690 Vac Grid Support Utilitity Interactive Inverters. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4654.418 kW
CEC Weighted Eff.
98%
MPPT / Max DC
955–1300V / 1300V
NEC 705.12 Breaker
4900A @ 690V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Gamesa Electric |
|---|---|
| Model Number (MPN) | PV4700 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 4654.418 kW (4,654,418 W) |
| Nominal DC Input (Pdco) | 4,758,940 W |
| Nominal AC Voltage | 690 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 955 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 4532.3 A |
| Night Tare Loss | 267 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3894.6 A @ 690V |
|---|---|
| 125% Continuous Duty Current | 4868.3 A |
| Minimum Standard Breaker | 4900 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (5119.86–6283.46 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 12800–15709 panels | 5120.0–6283.6 kW DC |
| 440W | 11636–14281 panels | 5119.8–6283.6 kW DC |
| 550W | 9309–11424 panels | 5119.9–6283.2 kW DC |
CEC-Listed 240V Equivalents to Gamesa Electric PV4700
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4654.418 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Gamesa Electric PV4700
What size circuit breaker does the Gamesa Electric PV4700 require under NEC 705.12?
At 4654.418 kW continuous AC output on 690V (3894.6A continuous), the 125% continuous duty rule requires a minimum 4900A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Gamesa Electric PV4700?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4654.418 kW unit with 5119.86 kW to 6283.46 kW DC of solar modules without exceeding 1300V cold Voc.