Growatt official logoCEC-Listed · 240V ResidentialString

Growatt 4000MTLP-US (4.05 kW)

4 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.05 kW
CEC Weighted Eff.
96%
MPPT / Max DC
100–550V / 550V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt 4000MTLP-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 100–550 Vdc 100V 550V MAX 550V PV DC INPUT ≤ 550V DC 4.05 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 25A BRKR

Electrical & Grid-Support Datasheet

Growatt 4000MTLP-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)4000MTLP-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)4.05 kW (4,050 W)
Nominal DC Input (Pdco)4,178 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V, 277V
CEC Weighted Efficiency96%
MPPT Operating Window100 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current8.7 A
Night Tare Loss0.05 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 4000MTLP-US
Max Continuous AC Current16.9 A @ 240V
125% Continuous Duty Current21.1 A
Minimum Standard Breaker25 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.46–5.47 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 4000MTLP-US
Panel ClassRecommended QtyDC Array / Ratio
400W11–14 panels4.4–5.6 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–10 panels4.4–5.5 kW DC

Compatible Solar Panels for Growatt 4000MTLP-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt 4000MTLP-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V3–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V3–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V3–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V3–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V3–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt 4000MTLP-US

What size circuit breaker does the Growatt 4000MTLP-US require under NEC 705.12?
At 4.05 kW continuous AC output on 240V (16.9A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt 4000MTLP-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.05 kW unit with 4.46 kW to 5.47 kW DC of solar modules without exceeding 550V cold Voc.

More Growatt Inverters

SPH 3600TL BL-US (3.608 kW)MIN 3800TL-XH-US (3.888 kW)SPH 4000TL BL-US (3.988 kW)SPH 4600TL BL-US (4.598 kW)MIN 5000TL-XH-US (4.943 kW)SPH 5000TL BL-US (4.954 kW)All Growatt Equipment →