Growatt official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

Growatt SPH 3600TL BL-US (3.608 kW)

3.61 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.608 kW
CEC Weighted Eff.
94%
MPPT / Max DC
150–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt SPH 3600TL BL-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 150–480 Vdc 150V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.608 kW · 94% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Growatt SPH 3600TL BL-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)SPH 3600TL BL-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.608 kW (3,608 W)
Nominal DC Input (Pdco)3,779 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency94%
MPPT Operating Window150 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current9.9 A
Night Tare Loss15.13 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SPH 3600TL BL-US
Max Continuous AC Current15 A @ 240V
125% Continuous Duty Current18.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (3.97–4.87 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SPH 3600TL BL-US
Panel ClassRecommended QtyDC Array / Ratio
400W10–12 panels4.0–4.8 kW DC
440W9–11 panels4.0–4.8 kW DC
550W7–9 panels3.9–5.0 kW DC

Compatible Solar Panels for Growatt SPH 3600TL BL-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt SPH 3600TL BL-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — Growatt SPH 3600TL BL-US

What size circuit breaker does the Growatt SPH 3600TL BL-US require under NEC 705.12?
At 3.608 kW continuous AC output on 240V (15A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Growatt SPH 3600TL BL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.608 kW unit with 3.97 kW to 4.87 kW DC of solar modules without exceeding 480V cold Voc.

More Growatt Inverters

MIN 11400TL-XH-US (11.52 kW)SPH 3000TL BL-US (2.934 kW)MIN 3000TL-XH-US (3.095 kW)MIN 3800TL-XH-US (3.888 kW)SPH 4000TL BL-US (3.988 kW)4000MTLP-US (4.05 kW)All Growatt Equipment →