Growatt official logoCEC-Listed · 240V ResidentialHybridBattery Hybrid

Growatt SPH 4000TL BL-US (3.988 kW)

3.99 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.988 kW
CEC Weighted Eff.
95%
MPPT / Max DC
180–480V / 480V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt SPH 4000TL BL-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 180–480 Vdc 180V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.988 kW · 95% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 25A BRKR

Electrical & Grid-Support Datasheet

Growatt SPH 4000TL BL-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)SPH 4000TL BL-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.988 kW (3,988 W)
Nominal DC Input (Pdco)4,158 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants240V, 208V
CEC Weighted Efficiency95%
MPPT Operating Window180 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current10.9 A
Night Tare Loss15.13 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SPH 4000TL BL-US
Max Continuous AC Current16.6 A @ 240V
125% Continuous Duty Current20.8 A
Minimum Standard Breaker25 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.39–5.38 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SPH 4000TL BL-US
Panel ClassRecommended QtyDC Array / Ratio
400W11–13 panels4.4–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–10 panels4.4–5.5 kW DC

Compatible Solar Panels for Growatt SPH 4000TL BL-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt SPH 4000TL BL-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — Growatt SPH 4000TL BL-US

What size circuit breaker does the Growatt SPH 4000TL BL-US require under NEC 705.12?
At 3.988 kW continuous AC output on 240V (16.6A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt SPH 4000TL BL-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.988 kW unit with 4.39 kW to 5.38 kW DC of solar modules without exceeding 480V cold Voc.

More Growatt Inverters

MIN 3000TL-XH-US (3.095 kW)SPH 3600TL BL-US (3.608 kW)MIN 3800TL-XH-US (3.888 kW)4000MTLP-US (4.05 kW)SPH 4600TL BL-US (4.598 kW)MIN 5000TL-XH-US (4.943 kW)All Growatt Equipment →