Growatt official logoCEC-Listed · 240V ResidentialString

Growatt 6000MTLP-US (6.08 kW)

6 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
6.08 kW
CEC Weighted Eff.
96%
MPPT / Max DC
100–550V / 550V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt 6000MTLP-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 100–550 Vdc 100V 550V MAX 550V PV DC INPUT ≤ 550V DC 6.08 kW · 96% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Growatt 6000MTLP-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)6000MTLP-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)6.08 kW (6,080 W)
Nominal DC Input (Pdco)6,291 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V, 277V
CEC Weighted Efficiency96%
MPPT Operating Window100 – 550 Vdc (NREL SAM Measured)
Max DC Input Voltage550 Vdc
Max DC Input Current13.1 A
Night Tare Loss0.05 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 6000MTLP-US
Max Continuous AC Current25.3 A @ 240V
125% Continuous Duty Current31.6 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.69–8.21 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 6000MTLP-US
Panel ClassRecommended QtyDC Array / Ratio
400W17–21 panels6.8–8.4 kW DC
440W15–19 panels6.6–8.4 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Growatt 6000MTLP-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt 6000MTLP-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V3–9 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V3–9 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V3–9 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V3–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V3–10 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–7 per string (-10°C)Verify Pair

Engineering FAQ — Growatt 6000MTLP-US

What size circuit breaker does the Growatt 6000MTLP-US require under NEC 705.12?
At 6.08 kW continuous AC output on 240V (25.3A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt 6000MTLP-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 6.08 kW unit with 6.69 kW to 8.21 kW DC of solar modules without exceeding 550V cold Voc.

More Growatt Inverters

5000MTLP-US (5.07 kW)SPH 6000TL BL-US (5.864 kW)MIN 6000TL-XH-US (5.918 kW)7000MTLP-US (7.011 kW)MIN 7600TL-XH-US (7.524 kW)7600MTLP-US (7.604 kW)All Growatt Equipment →