Growatt official logoCEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Growatt MIN 6000TL-XH-US (5.918 kW)

5.918 kW, 240 Vac Hybrid Grid Support Utility Interactive Inverter, with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.918 kW
CEC Weighted Eff.
97%
MPPT / Max DC
170–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt MIN 6000TL-XH-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 170–480 Vdc 170V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.918 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Growatt MIN 6000TL-XH-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)MIN 6000TL-XH-US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.918 kW (5,918 W)
Nominal DC Input (Pdco)6,085 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window170 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current16 A
Night Tare Loss1.59 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIN 6000TL-XH-US
Max Continuous AC Current24.7 A @ 240V
125% Continuous Duty Current30.9 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.51–7.99 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIN 6000TL-XH-US
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W15–18 panels6.6–7.9 kW DC
550W12–15 panels6.6–8.3 kW DC

Compatible Solar Panels for Growatt MIN 6000TL-XH-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt MIN 6000TL-XH-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V5–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V5–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V5–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V5–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V5–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V4–6 per string (-10°C)Verify Pair

Engineering FAQ — Growatt MIN 6000TL-XH-US

What size circuit breaker does the Growatt MIN 6000TL-XH-US require under NEC 705.12?
At 5.918 kW continuous AC output on 240V (24.7A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt MIN 6000TL-XH-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.918 kW unit with 6.51 kW to 7.99 kW DC of solar modules without exceeding 480V cold Voc.

More Growatt Inverters

SPH 5000TL BL-US (4.954 kW)5000MTLP-US (5.07 kW)SPH 6000TL BL-US (5.864 kW)6000MTLP-US (6.08 kW)7000MTLP-US (7.011 kW)MIN 7600TL-XH-US (7.524 kW)All Growatt Equipment →