Growatt official logoCEC-Listed · 240V ResidentialString

Growatt 7000MTLP-US (7.011 kW)

7 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
7.011 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
280–485V / 485V
NEC 705.12 Breaker
40A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Growatt 7000MTLP-US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 280–485 Vdc 280V 485V MAX 485V PV DC INPUT ≤ 485V DC 7.011 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 40A BRKR

Electrical & Grid-Support Datasheet

Growatt 7000MTLP-US Electrical and Grid-Support Specifications
ManufacturerGrowatt
Model Number (MPN)7000MTLP-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)7.011 kW (7,011 W)
Nominal DC Input (Pdco)6,366 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V, 277V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window280 – 485 Vdc (NREL SAM Measured)
Max DC Input Voltage485 Vdc
Max DC Input Current16.5 A
Night Tare Loss0.05 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for 7000MTLP-US
Max Continuous AC Current29.2 A @ 240V
125% Continuous Duty Current36.5 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (7.71–9.46 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for 7000MTLP-US
Panel ClassRecommended QtyDC Array / Ratio
400W19–24 panels7.6–9.6 kW DC
440W18–22 panels7.9–9.7 kW DC
550W14–17 panels7.7–9.3 kW DC

Compatible Solar Panels for Growatt 7000MTLP-US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Growatt 7000MTLP-US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Growatt 7000MTLP-US

What size circuit breaker does the Growatt 7000MTLP-US require under NEC 705.12?
At 7.011 kW continuous AC output on 240V (29.2A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Growatt 7000MTLP-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 7.011 kW unit with 7.71 kW to 9.46 kW DC of solar modules without exceeding 485V cold Voc.

More Growatt Inverters

SPH 6000TL BL-US (5.864 kW)MIN 6000TL-XH-US (5.918 kW)6000MTLP-US (6.08 kW)MIN 7600TL-XH-US (7.524 kW)7600MTLP-US (7.604 kW)MIN 7600TL-XH2 US (7.651 kW)All Growatt Equipment →