465 W, 96 half-cut cell double glass bifacial monocrystalline module, 1500V max system Vdc. Registry source: CEC PV Module List (Nov 2026) · CEC listing date: · Registry snapshot: .
STC / PTC Power
465W / 443.1W
Efficiency
24.09%
Voc / Vmp
36.4V / 30.34V
Max String (600V)
15 @ −10°C
System Design Actions
Match Compatible Inverters ↓
Electrical & Thermal Specifications (STC)
| Manufacturer | SEG Solar |
|---|---|
| Model Number (MPN) | SEG-465-BTE-BG |
| Cell Technology | Mono-c-Si (Bifacial) · 96 cells |
| Nameplate Power (Pmax STC) | 465 W |
| Real-World Output (PTC) | 443.1 W (95.3% of STC) |
| Module Efficiency | 24.09% (240.9 W/m²) |
| Open-Circuit Voltage (Voc) | 36.4 V |
| Maximum Power Voltage (Vmp) | 30.34 V |
| Short-Circuit Current (Isc) | 16.09 A (NEC 1.25× = 20.11 A) |
| Maximum Power Current (Imp) | 15.33 A |
| Temp. Coeff. Power (γPmax) | -0.29 %/°C |
| Temp. Coeff. Voltage (βVoc) | -0.237 %/°C |
| Temp. Coeff. Current (αIsc) | +0.055 %/°C |
| Nominal Cell Temp (NOCT) | 43.2 °C |
| Dimensions (L × W) | 1722 × 1134 mm (67.8" × 44.6") |
| Surface Area | 1.93 m² (20.8 sq ft) |
| Safety Listing | UL 61730 |
NEC 690.7 Cold-Weather Voc Limits
Computed using this module’s βVoc (-0.237%/°C) from 25°C STC baseline. Never exceed inverter maximum DC input voltage.
| Design Cold Temp | Cold Voc | Max / 600V | Max / 1000V |
|---|---|---|---|
| 25°C / 77°F STC Lab Standard | 36.4 V | 16 | 27 |
| 0°C / 32°F Freezing / Mild Winter | 38.56 V | 15 | 25 |
| -10°C / 14°F TX / Southeast / Mid-Atlantic | 39.42 V | 15 | 25 |
| -20°C / -4°F Northeast / Midwest Winter | 40.28 V | 14 | 24 |
| -30°C / -22°F Northern Plains / Mountain | 41.14 V | 14 | 24 |
Residential Array Roof Sizing
| Target Size | Panels Needed | Actual DC | Roof Footprint |
|---|---|---|---|
| 6 kW | 13 panels | 6.04 kW | 270 sq ft (25.1 m²) |
| 8 kW | 18 panels | 8.37 kW | 374 sq ft (34.7 m²) |
| 10 kW | 22 panels | 10.23 kW | 457 sq ft (42.5 m²) |
| 12 kW | 26 panels | 12.09 kW | 540 sq ft (50.2 m²) |
Compatible CEC-Listed Inverters for SEG-465-BTE-BG
Open full string calculator with this panel →| Inverter Model | Topology | AC Output | CEC Eff. | Compatibility Check (−10°C) | Action |
|---|---|---|---|---|---|
| APsystems ELS-3K | Hybrid | 3.685 kW | 94% | 2–15 panels/string at -10°C | Verify Pair |
| EG4 Electronics IV-8000-HYB-AW | Hybrid | 7.863 kW | 96.5% | 9–12 panels/string at -10°C | Verify Pair |
| Enphase Energy IQ7X-96-2-US | Microinverter | 0.315 kW | 97% | 1:1 micro pairing (1.48 DC/AC ratio) | Verify Pair |
| Fronius Primo GEN24 6.0 208-240 Plus SC | Hybrid | 6.005 kW | 97% | 5–15 panels/string at -10°C | Verify Pair |
| GoodWe GEC6.0-1U-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
| GoodWe GW6000-SBP-US20 | Hybrid | 6.01 kW | 96% | 5–12 panels/string at -10°C | Verify Pair |
Other Power Classes in This SEG Solar Series (6 total CEC variants)
| Series Variant Model | STC Power | PTC Power | Voc | Isc | Efficiency |
|---|---|---|---|---|---|
| SEG-440-BTE-BG | 440 W | 418.7 W | 35.47 V | 15.77 A | 22.8% |
| SEG-445-BTE-BG | 445 W | 423.6 W | 35.64 V | 15.83 A | 23.06% |
| SEG-450-BTE-BG | 450 W | 428.5 W | 35.82 V | 15.9 A | 23.32% |
| SEG-455-BTE-BG | 455 W | 433.3 W | 36 V | 15.96 A | 23.58% |
| SEG-460-BTE-BG | 460 W | 438.2 W | 36.2 V | 16.03 A | 23.83% |
Engineering FAQ — SEG Solar SEG-465-BTE-BG
How many SEG Solar SEG-465-BTE-BG panels can fit in one 600V string?
At -10°C (14°F) ambient, the SEG-465-BTE-BG open-circuit voltage rises from 36.4V to 39.42V (using βVoc -0.237%/°C), allowing up to 15 modules per series string on a 600V residential US inverter under NEC 690.7.
What is the real-world PTC output and efficiency of the SEG Solar SEG-465-BTE-BG?
Rated at 465W STC, the SEG-465-BTE-BG carries a 443.1W PTC rating (95.3% PTC/STC ratio) and 24.09% module efficiency across 1.93 m² (20.8 sq ft).
Is the SEG Solar SEG-465-BTE-BG listed in the CEC registry for US residential designs?
Yes. This module holds UL 61730 listing in the CEC registry (snapshot 2026-11-23) and is eligible for US residential kit modeling. Always confirm live distributor stock with your installer.