HM CEC-Listed · 240V ResidentialMicroinverter

Hoymiles HM-300NA (0.295 kW)

295 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.295 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
29–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HM-300NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 29–48 Vdc 29V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.295 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HM-300NA Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HM-300NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.295 kW (295 W)
Nominal DC Input (Pdco)306 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window29 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current7.7 A
Night Tare Loss0.11 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HM-300NA
Max Continuous AC Current1.2 A @ 240V
125% Continuous Duty Current1.5 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.32–0.4 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HM-300NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.36× DC/AC)
440W1 panel1:1 pairing (1.49× DC/AC)
550W1 panel1:1 pairing (1.86× DC/AC)

Compatible Solar Panels for Hoymiles HM-300NA

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles HM-300NA
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
REC Solar REC470AA Pure-RX-DC470 W65.7 VDC/AC 1.59 (1 panel/input)Verify Pair
SEG Solar SEG-465-BTE-BG465 W36.4 VDC/AC 1.58 (1 panel/input)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 VDC/AC 1.56 (1 panel/input)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 VDC/AC 1.56 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 VDC/AC 1.51 (1 panel/input)Verify Pair
Canadian Solar CS6.2-48TM-460H460 W36.2 VDC/AC 1.56 (1 panel/input)Verify Pair

Engineering FAQ — Hoymiles HM-300NA

What size circuit breaker does the Hoymiles HM-300NA require under NEC 705.12?
At 0.295 kW continuous AC output on 240V (1.2A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HM-300NA?
As a 295W microinverter, it pairs 1:1 with panels rated roughly 310W to 428W STC.

More Hoymiles Inverters

HYS-9.6LV-USG1 (9.641 kW)HYS-11.5LV-USG1 (11.575 kW)HM-300N (0.295 kW)HM-300NT (0.295 kW)HMS-350-1A-NA (0.322 kW)MIS-350-1NA (0.33 kW)All Hoymiles Equipment →