Hoymiles HM-700N (0.697 kW)
696 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.697 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
33–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Hoymiles |
|---|---|
| Model Number (MPN) | HM-700N |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.697 kW (697 W) |
| Nominal DC Input (Pdco) | 723 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 33 – 48 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 48 Vdc |
| Max DC Input Current | 17.2 A |
| Night Tare Loss | 0.11 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 2.9 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 3.6 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.77–0.94 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.57× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.63× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.79× DC/AC) |
Engineering FAQ — Hoymiles HM-700N
What size circuit breaker does the Hoymiles HM-700N require under NEC 705.12?
At 0.697 kW continuous AC output on 240V (2.9A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HM-700N?
As a 697W microinverter, it pairs 1:1 with panels rated roughly 732W to 1011W STC.