Hoymiles MIS-800-2NA (0.73 kW)
720 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
0.73 kW
CEC Weighted Eff.
97%
MPPT / Max DC
28–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Hoymiles |
|---|---|
| Model Number (MPN) | MIS-800-2NA |
| Inverter Topology | Microinverter |
| Continuous AC Power (Paco) | 0.73 kW (730 W) |
| Nominal DC Input (Pdco) | 754 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 28 – 48 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 48 Vdc |
| Max DC Input Current | 19.8 A |
| Night Tare Loss | 0.09 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 3.8 A |
| Minimum Standard Breaker | 15 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (0.8–0.99 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1 panel | 1:1 pairing (0.55× DC/AC) |
| 440W | 1 panel | 1:1 pairing (0.60× DC/AC) |
| 550W | 1 panel | 1:1 pairing (0.75× DC/AC) |
Engineering FAQ — Hoymiles MIS-800-2NA
What size circuit breaker does the Hoymiles MIS-800-2NA require under NEC 705.12?
At 0.73 kW continuous AC output on 240V (3A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles MIS-800-2NA?
As a 730W microinverter, it pairs 1:1 with panels rated roughly 767W to 1059W STC.