HM CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Hoymiles MIS-700-2NA (0.647 kW)

638 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.647 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
27–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles MIS-700-2NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 27–48 Vdc 27V 48V MAX 48V PV DC INPUT ≤ 48V DC 0.647 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles MIS-700-2NA Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)MIS-700-2NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.647 kW (647 W)
Nominal DC Input (Pdco)668 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window27 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current18.1 A
Night Tare Loss0.09 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for MIS-700-2NA
Max Continuous AC Current2.7 A @ 240V
125% Continuous Duty Current3.4 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.71–0.87 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for MIS-700-2NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.62× DC/AC)
440W1 panel1:1 pairing (0.68× DC/AC)
550W1 panel1:1 pairing (0.85× DC/AC)

Engineering FAQ — Hoymiles MIS-700-2NA

What size circuit breaker does the Hoymiles MIS-700-2NA require under NEC 705.12?
At 0.647 kW continuous AC output on 240V (2.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles MIS-700-2NA?
As a 647W microinverter, it pairs 1:1 with panels rated roughly 679W to 938W STC.