HM CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Hoymiles HMS-1800-4T-NA (1.668 kW)

1660 W, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1.668 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
32–48V / 48V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HMS-1800-4T-NA — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 32–48 Vdc 32V 48V MAX 48V PV DC INPUT ≤ 48V DC 1.668 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HMS-1800-4T-NA Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HMS-1800-4T-NA
Inverter TopologyMicroinverter
Continuous AC Power (Paco)1.668 kW (1,668 W)
Nominal DC Input (Pdco)1,736 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window32 – 48 Vdc (NREL SAM Measured)
Max DC Input Voltage48 Vdc
Max DC Input Current41.3 A
Night Tare Loss0.11 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HMS-1800-4T-NA
Max Continuous AC Current7 A @ 240V
125% Continuous Duty Current8.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.83–2.25 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HMS-1800-4T-NA
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.24× DC/AC)
440W1 panel1:1 pairing (0.26× DC/AC)
550W1 panel1:1 pairing (0.33× DC/AC)

Engineering FAQ — Hoymiles HMS-1800-4T-NA

What size circuit breaker does the Hoymiles HMS-1800-4T-NA require under NEC 705.12?
At 1.668 kW continuous AC output on 240V (7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HMS-1800-4T-NA?
As a 1668W microinverter, it pairs 1:1 with panels rated roughly 1751W to 2419W STC.

More Hoymiles Inverters

HM-1500N (1.439 kW)HMS-1600-4T-NA (1.447 kW)HMS-1500-4D (1.551 kW)HMS-2000-4T-NA (1.928 kW)HAS-3.8LV-USG1 (3.646 kW)HYS-3.8LV-USG1 (3.796 kW)All Hoymiles Equipment →