Hoymiles HYS-3.8LV-USG1 (3.796 kW)

3.8 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.796 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–480V / 480V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HYS-3.8LV-USG1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 300–480 Vdc 300V 480V MAX 480V PV DC INPUT ≤ 480V DC 3.796 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HYS-3.8LV-USG1 Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HYS-3.8LV-USG1
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.796 kW (3,796 W)
Nominal DC Input (Pdco)3,902 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window300 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current10.3 A
Night Tare Loss6.04 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HYS-3.8LV-USG1
Max Continuous AC Current15.8 A @ 240V
125% Continuous Duty Current19.8 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.18–5.12 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HYS-3.8LV-USG1
Panel ClassRecommended QtyDC Array / Ratio
400W10–13 panels4.0–5.2 kW DC
440W10–12 panels4.4–5.3 kW DC
550W8–9 panels4.4–5.0 kW DC

Compatible Solar Panels for Hoymiles HYS-3.8LV-USG1

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles HYS-3.8LV-USG1
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-520MB-AG520 W48.4 V9–9 per string (-10°C)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 V11–11 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V12–12 per string (-10°C)Verify Pair

Engineering FAQ — Hoymiles HYS-3.8LV-USG1

What size circuit breaker does the Hoymiles HYS-3.8LV-USG1 require under NEC 705.12?
At 3.796 kW continuous AC output on 240V (15.8A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HYS-3.8LV-USG1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.796 kW unit with 4.18 kW to 5.12 kW DC of solar modules without exceeding 480V cold Voc.