HM CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Hoymiles HAS-3.8LV-USG1 (3.646 kW)

3.8 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
3.646 kW
CEC Weighted Eff.
93.5%
MPPT / Max DC
120–500V / 600V
NEC 705.12 Breaker
20A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HAS-3.8LV-USG1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 3.646 kW · 93.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 20A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HAS-3.8LV-USG1 Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HAS-3.8LV-USG1
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)3.646 kW (3,646 W)
Nominal DC Input (Pdco)3,846 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency93.5%
MPPT Operating Window120 – 500 Vdc (NREL SAM Measured)
Max DC Input Voltage600 Vdc
Max DC Input Current69.9 A
Night Tare Loss5.99 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HAS-3.8LV-USG1
Max Continuous AC Current15.2 A @ 240V
125% Continuous Duty Current19.0 A
Minimum Standard Breaker20 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (4.01–4.92 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HAS-3.8LV-USG1
Panel ClassRecommended QtyDC Array / Ratio
400W10–12 panels4.0–4.8 kW DC
440W9–11 panels4.0–4.8 kW DC
550W7–9 panels3.9–5.0 kW DC

Compatible Solar Panels for Hoymiles HAS-3.8LV-USG1

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles HAS-3.8LV-USG1
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Hoymiles HAS-3.8LV-USG1

What size circuit breaker does the Hoymiles HAS-3.8LV-USG1 require under NEC 705.12?
At 3.646 kW continuous AC output on 240V (15.2A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Hoymiles HAS-3.8LV-USG1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3.646 kW unit with 4.01 kW to 4.92 kW DC of solar modules without exceeding 600V cold Voc.

More Hoymiles Inverters

HMS-1500-4D (1.551 kW)HMS-1800-4T-NA (1.668 kW)HMS-2000-4T-NA (1.928 kW)HYS-3.8LV-USG1 (3.796 kW)HAS-4.8LV-USG1 (4.559 kW)HYS-4.8LV-USG1 (4.793 kW)All Hoymiles Equipment →