4.8 kW, 240 Vac Grid Support Utility Interactive Hybrid Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
4.793 kW
CEC Weighted Eff.
97%
MPPT / Max DC
300–480V / 480V
NEC 705.12 Breaker
25A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Hoymiles HYS-4.8LV-USG1 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 300–480 Vdc 300V 480V MAX 480V PV DC INPUT ≤ 480V DC 4.793 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 25A BRKR

Electrical & Grid-Support Datasheet

Hoymiles HYS-4.8LV-USG1 Electrical and Grid-Support Specifications
ManufacturerHoymiles
Model Number (MPN)HYS-4.8LV-USG1
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)4.793 kW (4,793 W)
Nominal DC Input (Pdco)4,931 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window300 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current13 A
Night Tare Loss5.76 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for HYS-4.8LV-USG1
Max Continuous AC Current20 A @ 240V
125% Continuous Duty Current25.0 A
Minimum Standard Breaker25 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (5.27–6.47 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for HYS-4.8LV-USG1
Panel ClassRecommended QtyDC Array / Ratio
400W13–16 panels5.2–6.4 kW DC
440W12–15 panels5.3–6.6 kW DC
550W10–12 panels5.5–6.6 kW DC

Compatible Solar Panels for Hoymiles HYS-4.8LV-USG1

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Hoymiles HYS-4.8LV-USG1
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-520MB-AG520 W48.4 V9–9 per string (-10°C)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 V11–11 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V12–12 per string (-10°C)Verify Pair

Engineering FAQ — Hoymiles HYS-4.8LV-USG1

What size circuit breaker does the Hoymiles HYS-4.8LV-USG1 require under NEC 705.12?
At 4.793 kW continuous AC output on 240V (20A continuous), the 125% continuous duty rule requires a minimum 25A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Hoymiles HYS-4.8LV-USG1?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4.793 kW unit with 5.27 kW to 6.47 kW DC of solar modules without exceeding 480V cold Voc.