Ingeteam INGECON SUN 3825TL U C615 (3219.88 kW)
3219 kW, 615 Vac, Bi-directional, Grid Support Utility Interactive PV Inverter with External Transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
3219.88 kW
CEC Weighted Eff.
98%
MPPT / Max DC
877–1300V / 1300V
NEC 705.12 Breaker
3800A @ 615V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Ingeteam |
|---|---|
| Model Number (MPN) | INGECON SUN 3825TL U C615 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 3219.88 kW (3,219,880 W) |
| Nominal DC Input (Pdco) | 3,297,440 W |
| Nominal AC Voltage | 615 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 877 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 2794.4 A |
| Night Tare Loss | 2892.52 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3022.9 A @ 615V |
|---|---|
| 125% Continuous Duty Current | 3778.6 A |
| Minimum Standard Breaker | 3800 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (3541.87–4346.84 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 8855–10867 panels | 3542.0–4346.8 kW DC |
| 440W | 8050–9879 panels | 3542.0–4346.8 kW DC |
| 550W | 6440–7903 panels | 3542.0–4346.6 kW DC |
CEC-Listed 240V Equivalents to Ingeteam INGECON SUN 3825TL U C615
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (3219.88 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Ingeteam INGECON SUN 3825TL U C615
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-460-BTD-HV | 460 W | 39.94 V | 30–30 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 33–34 per string (-10°C) | Verify Pair |
| REC Solar REC430AA Pure 2 | 430 W | 49 V | 24–24 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM-R | 435 W | 40.7 V | 29–29 per string (-10°C) | Verify Pair |
Engineering FAQ — Ingeteam INGECON SUN 3825TL U C615
What size circuit breaker does the Ingeteam INGECON SUN 3825TL U C615 require under NEC 705.12?
At 3219.88 kW continuous AC output on 615V (3022.9A continuous), the 125% continuous duty rule requires a minimum 3800A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Ingeteam INGECON SUN 3825TL U C615?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 3219.88 kW unit with 3541.87 kW to 4346.84 kW DC of solar modules without exceeding 1300V cold Voc.