Ingeteam INGECON SUN 610TL U B220 (610 kW)
610 kW, 220 Vac Grid Support Utility Interactive Inverter for PV and Battery Applications. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
610 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
440–740V / 740V
NEC 705.12 Breaker
2100A @ 220V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Ingeteam |
|---|---|
| Model Number (MPN) | INGECON SUN 610TL U B220 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 610 kW (610,000 W) |
| Nominal DC Input (Pdco) | 630,094 W |
| Nominal AC Voltage | 220 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 440 – 740 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 740 Vdc |
| Max DC Input Current | 1068 A |
| Night Tare Loss | 80 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 1600.9 A @ 220V |
|---|---|
| 125% Continuous Duty Current | 2001.1 A |
| Minimum Standard Breaker | 2100 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (671–823.5 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1678–2059 panels | 671.2–823.6 kW DC |
| 440W | 1525–1872 panels | 671.0–823.7 kW DC |
| 550W | 1220–1497 panels | 671.0–823.4 kW DC |
CEC-Listed 240V Equivalents to Ingeteam INGECON SUN 610TL U B220
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (610 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Ingeteam INGECON SUN 610TL U B220
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 12–13 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 12–13 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 12–12 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 13–13 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 13–13 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 10–10 per string (-10°C) | Verify Pair |
Engineering FAQ — Ingeteam INGECON SUN 610TL U B220
What size circuit breaker does the Ingeteam INGECON SUN 610TL U B220 require under NEC 705.12?
At 610 kW continuous AC output on 220V (1600.9A continuous), the 125% continuous duty rule requires a minimum 2100A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Ingeteam INGECON SUN 610TL U B220?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 610 kW unit with 671 kW to 823.5 kW DC of solar modules without exceeding 740V cold Voc.