LE CEC-Listed · Commercial / C&IMicroinverter

LeadSolar Energy LS700S (0.606 kW)

600W, 208 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.606 kW
CEC Weighted Eff.
95.5%
MPPT / Max DC
52–56V / 56V
NEC 705.12 Breaker
15A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
LeadSolar Energy LS700S — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 52–56 Vdc 52V 56V MAX 56V PV DC INPUT ≤ 56V DC 0.606 kW · 95.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 208V · 15A BRKR

Electrical & Grid-Support Datasheet

LeadSolar Energy LS700S Electrical and Grid-Support Specifications
ManufacturerLeadSolar Energy
Model Number (MPN)LS700S
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.606 kW (606 W)
Nominal DC Input (Pdco)635 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency95.5%
MPPT Operating Window52 – 56 Vdc (NREL SAM Measured)
Max DC Input Voltage56 Vdc
Max DC Input Current11.8 A
Night Tare Loss0.21 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for LS700S
Max Continuous AC Current1.7 A @ 208V
125% Continuous Duty Current2.1 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.67–0.82 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for LS700S
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.66× DC/AC)
440W1 panel1:1 pairing (0.73× DC/AC)
550W1 panel1:1 pairing (0.91× DC/AC)

CEC-Listed 240V Equivalents to LeadSolar Energy LS700S

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (0.606 kW Microinverter) and can be added directly to your US System Kit:

CEC-Listed · 240V0.604 kW
Cherry Solution · Microinverter

CMI-600S-SA

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.604 kW
HYXI Power · Microinverter

HYX-M600-S

CEC Efficiency: 96.5%
Datasheet →
CEC-Listed · 240V0.594 kW
SolaX Power · Microinverter

A1-Micro 600P

CEC Efficiency: 94%
Datasheet →

Compatible Solar Panels for LeadSolar Energy LS700S

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for LeadSolar Energy LS700S
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 VDC/AC 0.96 (1 panel/input)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 VDC/AC 0.96 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 VDC/AC 0.95 (1 panel/input)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 VDC/AC 0.92 (1 panel/input)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 VDC/AC 0.92 (1 panel/input)Verify Pair
Trina Solar TSM-565NE19RC565 W46.3 VDC/AC 0.93 (1 panel/input)Verify Pair

Engineering FAQ — LeadSolar Energy LS700S

What size circuit breaker does the LeadSolar Energy LS700S require under NEC 705.12?
At 0.606 kW continuous AC output on 208V (1.7A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the LeadSolar Energy LS700S?
As a 606W microinverter, it pairs 1:1 with panels rated roughly 636W to 879W STC.

More LeadSolar Energy Inverters

LS600 (0.5 kW)LS600X (0.708 kW)All LeadSolar Energy Equipment →