LG Electronics / LG Energy SHB-G1-114-US (11.392 kW)
11.4 kW, 240 Vac, Bi-directional, Transformerless Grid Support Utility Interactive Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
11.392 kW
CEC Weighted Eff.
96%
MPPT / Max DC
235–495V / 495V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Legacy / Replacement Reference: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | LG Electronics / LG Energy |
|---|---|
| Model Number (MPN) | SHB-G1-114-US |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 11.392 kW (11,392 W) |
| Nominal DC Input (Pdco) | 11,909 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| CEC Weighted Efficiency | 96% |
| MPPT Operating Window | 235 – 495 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 495 Vdc |
| Max DC Input Current | 39.7 A |
| Night Tare Loss | 5.61 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | CSA Group |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 47.5 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 59.4 A |
| Minimum Standard Breaker | 60 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (12.53–15.38 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 31–38 panels | 12.4–15.2 kW DC |
| 440W | 28–35 panels | 12.3–15.4 kW DC |
| 550W | 23–28 panels | 12.7–15.4 kW DC |
CEC-Listed 240V Equivalents to LG Electronics / LG Energy SHB-G1-114-US
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (11.392 kW Hybrid Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for LG Electronics / LG Energy SHB-G1-114-US
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–8 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–8 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–8 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–9 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–9 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–6 per string (-10°C) | Verify Pair |
Engineering FAQ — LG Electronics / LG Energy SHB-G1-114-US
What size circuit breaker does the LG Electronics / LG Energy SHB-G1-114-US require under NEC 705.12?
At 11.392 kW continuous AC output on 240V (47.5A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the LG Electronics / LG Energy SHB-G1-114-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.392 kW unit with 12.53 kW to 15.38 kW DC of solar modules without exceeding 495V cold Voc.