LE CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Lion Energy Hybrid Inverter 12kW (8.084 kW)

12 kW, 240 Vac Grid Support Hybrid Utility Interactive Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
8.084 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
250–430V / 430V
NEC 705.12 Breaker
45A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Lion Energy Hybrid Inverter 12kW — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 250–430 Vdc 250V 430V MAX 430V PV DC INPUT ≤ 430V DC 8.084 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 45A BRKR

Electrical & Grid-Support Datasheet

Lion Energy Hybrid Inverter 12kW Electrical and Grid-Support Specifications
ManufacturerLion Energy
Model Number (MPN)Hybrid Inverter 12kW
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)8.084 kW (8,084 W)
Nominal DC Input (Pdco)8,327 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window250 – 430 Vdc (NREL SAM Measured)
Max DC Input Voltage430 Vdc
Max DC Input Current23.1 A
Night Tare Loss17.4 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Hybrid Inverter 12kW
Max Continuous AC Current33.7 A @ 240V
125% Continuous Duty Current42.1 A
Minimum Standard Breaker45 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (8.89–10.91 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Hybrid Inverter 12kW
Panel ClassRecommended QtyDC Array / Ratio
400W22–27 panels8.8–10.8 kW DC
440W20–25 panels8.8–11.0 kW DC
550W16–20 panels8.8–11.0 kW DC

Compatible Solar Panels for Lion Energy Hybrid Inverter 12kW

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Lion Energy Hybrid Inverter 12kW
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V7–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V7–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V7–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V7–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V7–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Lion Energy Hybrid Inverter 12kW

What size circuit breaker does the Lion Energy Hybrid Inverter 12kW require under NEC 705.12?
At 8.084 kW continuous AC output on 240V (33.7A continuous), the 125% continuous duty rule requires a minimum 45A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Lion Energy Hybrid Inverter 12kW?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 8.084 kW unit with 8.89 kW to 10.91 kW DC of solar modules without exceeding 430V cold Voc.

More Lion Energy Inverters

Sanctuary 3 Inverter 24kW (16.199 kW)#50170167 Sanctuary 8K (7.898 kW)#50170168 (8.084 kW)Sanctuary 3 Inverter 12kW (8.181 kW)Hybrid Inverter 15kW (10.177 kW)Sanctuary 3 Inverter 18kW (12.214 kW)All Lion Energy Equipment →