Maxeon / SunPower SPR-12000m-3 (12 kW)
Sunny Tripower TL-US 12 kW, 480 Vac 3-phase, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
12 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
300–800V / 800V
NEC 705.12 Breaker
20A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Maxeon / SunPower |
|---|---|
| Model Number (MPN) | SPR-12000m-3 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 12 kW (12,000 W) |
| Nominal DC Input (Pdco) | 12,274 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 300 – 800 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 800 Vdc |
| Max DC Input Current | 18.2 A |
| Night Tare Loss | 1.79 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | Yes |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 14.4 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 18.0 A |
| Minimum Standard Breaker | 20 A |
| Busbar Requirement | 100A Busbar (120% rule: up to 20A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (13.2–16.2 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 33–41 panels | 13.2–16.4 kW DC |
| 440W | 30–37 panels | 13.2–16.3 kW DC |
| 550W | 24–29 panels | 13.2–15.9 kW DC |
CEC-Listed 240V Equivalents to Maxeon / SunPower SPR-12000m-3
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (12 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
Compatible Solar Panels for Maxeon / SunPower SPR-12000m-3
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 8–14 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 8–14 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 8–13 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 9–14 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 9–14 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 7–11 per string (-10°C) | Verify Pair |
Engineering FAQ — Maxeon / SunPower SPR-12000m-3
What size circuit breaker does the Maxeon / SunPower SPR-12000m-3 require under NEC 705.12?
At 12 kW continuous AC output on 480V (14.4A continuous), the 125% continuous duty rule requires a minimum 20A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Maxeon / SunPower SPR-12000m-3?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12 kW unit with 13.2 kW to 16.2 kW DC of solar modules without exceeding 800V cold Voc.