SolarEdge official logoCEC-Listed · 240V ResidentialString

SolarEdge SE11400A-US (11.39 kW)

11.4 kW, 240 Vac, 1-phase Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.39 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
360–480V / 480V
NEC 705.12 Breaker
60A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
SolarEdge SE11400A-US — Real SolarEdge solar inverter installation
Real SolarEdge solar inverter installationWikimedia Commons — File:SolarEdge-Verdrahtungsbeispiel-01.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 360–480 Vdc 360V 480V MAX 480V PV DC INPUT ≤ 480V DC 11.39 kW · 97.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 60A BRKR

Electrical & Grid-Support Datasheet

SolarEdge SE11400A-US Electrical and Grid-Support Specifications
ManufacturerSolarEdge
Model Number (MPN)SE11400A-US
Inverter TopologyString Inverter
Continuous AC Power (Paco)11.39 kW (11,390 W)
Nominal DC Input (Pdco)11,707 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window360 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current29.3 A
Night Tare Loss5.95 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SE11400A-US
Max Continuous AC Current47.5 A @ 240V
125% Continuous Duty Current59.4 A
Minimum Standard Breaker60 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.53–15.38 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SE11400A-US
Panel ClassRecommended QtyDC Array / Ratio
400W31–38 panels12.4–15.2 kW DC
440W28–35 panels12.3–15.4 kW DC
550W23–28 panels12.7–15.4 kW DC

Engineering FAQ — SolarEdge SE11400A-US

What size circuit breaker does the SolarEdge SE11400A-US require under NEC 705.12?
At 11.39 kW continuous AC output on 240V (47.5A continuous), the 125% continuous duty rule requires a minimum 60A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the SolarEdge SE11400A-US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.39 kW unit with 12.53 kW to 15.38 kW DC of solar modules without exceeding 480V cold Voc.

More SolarEdge Inverters

SE10000A-US (9.94 kW)SE10000H-US (9.994 kW)NX10000T-US (10 kW)SE11400H-US (11.393 kW)NX11500T-US (11.52 kW)NX13000T-US (13 kW)All SolarEdge Equipment →