Fronius official logoCEC-Listed · 240V ResidentialString

Fronius Symo 12.0-3 208-240 (12 kW)

12 kW, 240 Vac, three phase Grid Support Utility Interactive Inverter with arc detector and meter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
12 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
300–480V / 480V
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Fronius Symo 12.0-3 208-240 — Real Fronius solar inverter installation
Real Fronius solar inverter installationWikimedia Commons — File:Bregenz-Vorarlberger Kraftwerke-Inverter Test bay-Fronius Ohmpilot 9 0-3-01ASD.jpg (CC BY-SA 4.0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 300–480 Vdc 300V 480V MAX 480V PV DC INPUT ≤ 480V DC 12 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Fronius Symo 12.0-3 208-240 Electrical and Grid-Support Specifications
ManufacturerFronius
Model Number (MPN)Symo 12.0-3 208-240
Inverter TopologyString Inverter
Continuous AC Power (Paco)12 kW (12,000 W)
Nominal DC Input (Pdco)12,455 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window300 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current33.7 A
Night Tare Loss0.81 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Symo 12.0-3 208-240
Max Continuous AC Current50 A @ 240V
125% Continuous Duty Current62.5 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.2–16.2 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Symo 12.0-3 208-240
Panel ClassRecommended QtyDC Array / Ratio
400W33–41 panels13.2–16.4 kW DC
440W30–37 panels13.2–16.3 kW DC
550W24–29 panels13.2–15.9 kW DC

Compatible Solar Panels for Fronius Symo 12.0-3 208-240

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Fronius Symo 12.0-3 208-240
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-520MB-AG520 W48.4 V9–9 per string (-10°C)Verify Pair
Mission Solar MSX10-460HN0B {C}460 W39.3 V11–11 per string (-10°C)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 V12–12 per string (-10°C)Verify Pair

Engineering FAQ — Fronius Symo 12.0-3 208-240

What size circuit breaker does the Fronius Symo 12.0-3 208-240 require under NEC 705.12?
At 12 kW continuous AC output on 240V (50A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Fronius Symo 12.0-3 208-240?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 12 kW unit with 13.2 kW to 16.2 kW DC of solar modules without exceeding 480V cold Voc.

More Fronius Inverters

Primo GEN24 10.0 208-240 (10.019 kW)Symo Advanced 10.0-3 208-240 (10.062 kW)Primo 11.4-1 208-240 (11.4 kW)Symo Advanced 12.0-3 208-240 (12.09 kW)Primo 12.5-1 208-240 (12.5 kW)Primo 15.0-1 208-240 (15 kW)All Fronius Equipment →