Pika Energy X11402 (11.187 kW)

11.4 kW, 208 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.187 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
390–420V / 420V
NEC 705.12 Breaker
40A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Pika Energy X11402 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 390–420 Vdc 390V 420V MAX 420V PV DC INPUT ≤ 420V DC 11.187 kW · 97.5% CEC PV + BATTERY HYBRID AC OUTPUT 208V · 40A BRKR

Electrical & Grid-Support Datasheet

Pika Energy X11402 Electrical and Grid-Support Specifications
ManufacturerPika Energy
Model Number (MPN)X11402
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.187 kW (11,187 W)
Nominal DC Input (Pdco)11,534 W
Nominal AC Voltage208 Vac (3-Phase)
CEC Weighted Efficiency97.5%
MPPT Operating Window390 – 420 Vdc (NREL SAM Measured)
Max DC Input Voltage420 Vdc
Max DC Input Current28.8 A
Night Tare Loss0.13 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for X11402
Max Continuous AC Current31.1 A @ 208V
125% Continuous Duty Current38.9 A
Minimum Standard Breaker40 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (12.31–15.1 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for X11402
Panel ClassRecommended QtyDC Array / Ratio
400W31–38 panels12.4–15.2 kW DC
440W28–34 panels12.3–15.0 kW DC
550W22–27 panels12.1–14.8 kW DC

CEC-Listed 240V Equivalents to Pika Energy X11402

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (11.187 kW Hybrid Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V11.147 kW
HYXI Power · Hybrid

HYX-H-HSPA

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V11.257 kW
Jiangsu Weiheng Intelligent Technology · Hybrid

SHD-11.4kW

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V11.257 kW
SunPluto Energy · Hybrid

SP-SHD-11.4kW

CEC Efficiency: 97%
Datasheet →

Engineering FAQ — Pika Energy X11402

What size circuit breaker does the Pika Energy X11402 require under NEC 705.12?
At 11.187 kW continuous AC output on 208V (31.1A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Pika Energy X11402?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.187 kW unit with 12.31 kW to 15.1 kW DC of solar modules without exceeding 420V cold Voc.