Pika Energy X11403 (11.18 kW)
11.4 kW, 208 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
11.18 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
390–420V / 420V
NEC 705.12 Breaker
40A @ 208V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Pika Energy |
|---|---|
| Model Number (MPN) | X11403 |
| Inverter Topology | String Inverter |
| Continuous AC Power (Paco) | 11.18 kW (11,180 W) |
| Nominal DC Input (Pdco) | 11,527 W |
| Nominal AC Voltage | 208 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 390 – 420 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 420 Vdc |
| Max DC Input Current | 28.8 A |
| Night Tare Loss | 0.13 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 31 A @ 208V |
|---|---|
| 125% Continuous Duty Current | 38.8 A |
| Minimum Standard Breaker | 40 A |
| Busbar Requirement | 200A Busbar (120% rule: up to 40A backfeed) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (12.3–15.09 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 31–38 panels | 12.4–15.2 kW DC |
| 440W | 28–34 panels | 12.3–15.0 kW DC |
| 550W | 22–27 panels | 12.1–14.8 kW DC |
CEC-Listed 240V Equivalents to Pika Energy X11403
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (11.18 kW String Inverter) and can be added directly to your US System Kit:
Engineering FAQ — Pika Energy X11403
What size circuit breaker does the Pika Energy X11403 require under NEC 705.12?
At 11.18 kW continuous AC output on 208V (31A continuous), the 125% continuous duty rule requires a minimum 40A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Pika Energy X11403?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.18 kW unit with 12.3 kW to 15.09 kW DC of solar modules without exceeding 420V cold Voc.