PC CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Power Center D350-M1A-240A (0.346 kW)

350 VA, 240 Vac Grid Support Utility Interactive Microinverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.346 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
22–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Power Center D350-M1A-240A — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 22–55 Vdc 22V 55V MAX 55V PV DC INPUT ≤ 55V DC 0.346 kW · 96.5% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Power Center D350-M1A-240A Electrical and Grid-Support Specifications
ManufacturerPower Center
Model Number (MPN)D350-M1A-240A
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.346 kW (346 W)
Nominal DC Input (Pdco)359 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window22 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current10.3 A
Night Tare Loss0.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for D350-M1A-240A
Max Continuous AC Current1.4 A @ 240V
125% Continuous Duty Current1.8 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (0.38–0.47 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for D350-M1A-240A
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (1.16× DC/AC)
440W1 panel1:1 pairing (1.27× DC/AC)
550W1 panel1:1 pairing (1.59× DC/AC)

Compatible Solar Panels for Power Center D350-M1A-240A

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Power Center D350-M1A-240A
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Mission Solar MSH10-550HT4T {B}550 W49.8 VDC/AC 1.59 (1 panel/input)Verify Pair
Canadian Solar CS6W-550MB-AG550 W49.6 VDC/AC 1.59 (1 panel/input)Verify Pair
SEG Solar SEG-545-BTC-BG545 W48.2 VDC/AC 1.58 (1 panel/input)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 VDC/AC 1.37 (1 panel/input)Verify Pair
Trina Solar TSM-460NEG9RH.25460 W36.3 VDC/AC 1.33 (1 panel/input)Verify Pair
Qcells (Hanwha) Q.TRON BLK M-G2.D+ 445445 W40.16 VDC/AC 1.29 (1 panel/input)Verify Pair

Engineering FAQ — Power Center D350-M1A-240A

What size circuit breaker does the Power Center D350-M1A-240A require under NEC 705.12?
At 0.346 kW continuous AC output on 240V (1.4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Power Center D350-M1A-240A?
As a 346W microinverter, it pairs 1:1 with panels rated roughly 363W to 502W STC.

More Power Center Inverters

Flex 10 (9.991 kW)Flex 12 (11.969 kW)Max Hybrid 15 (15.04 kW)D350-M1 (0.349 kW)D400-M1A-240A (0.398 kW)D600-M2A-240A (0.576 kW)All Power Center Equipment →