PC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery HybridEstimated MPPT — Verify Manufacturer Datasheet

Power Center Flex 12 (11.969 kW)

12 kW, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
11.969 kW
CEC Weighted Eff.
97%
MPPT / Max DC
120–500V / 600VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
70A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Power Center Flex 12 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 120–500 Vdc 120V 500V MAX 600V PV DC INPUT ≤ 600V DC 11.969 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 70A BRKR

Electrical & Grid-Support Datasheet

Power Center Flex 12 Electrical and Grid-Support Specifications
ManufacturerPower Center
Model Number (MPN)Flex 12
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)11.969 kW (11,969 W)
Nominal DC Input (Pdco)12,339 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency97%
MPPT Operating Window120 – 500 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design
Max DC Input Voltage600 Vdc
Max DC Input Current38.2 A
Night Tare Loss16.48 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SACertified
Certifying LaboratoryIntertek
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Flex 12
Max Continuous AC Current49.9 A @ 240V
125% Continuous Duty Current62.4 A
Minimum Standard Breaker70 A
Busbar Requirement200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (13.17–16.16 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Flex 12
Panel ClassRecommended QtyDC Array / Ratio
400W33–40 panels13.2–16.0 kW DC
440W30–37 panels13.2–16.3 kW DC
550W24–29 panels13.2–15.9 kW DC

Compatible Solar Panels for Power Center Flex 12

Test any of 3,007 panels with this inverter →
Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (120–500 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
Compatible Solar Panels for Power Center Flex 12
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V4–10 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V4–10 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V4–10 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V4–10 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V4–11 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V3–8 per string (-10°C)Verify Pair

Engineering FAQ — Power Center Flex 12

What size circuit breaker does the Power Center Flex 12 require under NEC 705.12?
At 11.969 kW continuous AC output on 240V (49.9A continuous), the 125% continuous duty rule requires a minimum 70A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Power Center Flex 12?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 11.969 kW unit with 13.17 kW to 16.16 kW DC of solar modules without exceeding 600V cold Voc.

More Power Center Inverters

D1500-M4 (1.439 kW)Essential Hybrid 5 (7.97 kW)Flex 10 (9.991 kW)Max Hybrid 15 (15.04 kW)D350-M1A-240A (0.346 kW)D350-M1 (0.349 kW)All Power Center Equipment →