Power Center Max Hybrid 15 (15.04 kW)
15 kW, 240 Vac Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
15.04 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–425V / 425V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Center |
|---|---|
| Model Number (MPN) | Max Hybrid 15 |
| Inverter Topology | Hybrid Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 15.04 kW (15,040 W) |
| Nominal DC Input (Pdco) | 15,606 W |
| Nominal AC Voltage | 240 Vac (Split/Single-Phase) |
| Listed Voltage Variants | 208V, 240V |
| CEC Weighted Efficiency | 96.5% (Class Estimate — Not listed in CEC) |
| MPPT Operating Window | 200 – 425 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 425 Vdc |
| Max DC Input Current | 48.8 A |
| Night Tare Loss | 21.2 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | SGS |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 62.7 A @ 240V |
|---|---|
| 125% Continuous Duty Current | 78.4 A |
| Minimum Standard Breaker | 80 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (16.54–20.3 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 41–51 panels | 16.4–20.4 kW DC |
| 440W | 38–46 panels | 16.7–20.2 kW DC |
| 550W | 30–37 panels | 16.5–20.4 kW DC |
Compatible Solar Panels for Power Center Max Hybrid 15
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 6–7 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 6–7 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 6–7 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 6–7 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 6–7 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 5–5 per string (-10°C) | Verify Pair |
Engineering FAQ — Power Center Max Hybrid 15
What size circuit breaker does the Power Center Max Hybrid 15 require under NEC 705.12?
At 15.04 kW continuous AC output on 240V (62.7A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Center Max Hybrid 15?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 15.04 kW unit with 16.54 kW to 20.3 kW DC of solar modules without exceeding 425V cold Voc.