PC CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Power Center Max Hybrid 15 (15.04 kW)

15 kW, 240 Vac Grid Support Utility Interactive PV and Battery Inverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
15.04 kW
CEC Weighted Eff.
96.5%Class Estimate
MPPT / Max DC
200–425V / 425V
NEC 705.12 Breaker
80A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Power Center Max Hybrid 15 — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 200–425 Vdc 200V 425V MAX 425V PV DC INPUT ≤ 425V DC 15.04 kW · 96.5% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 80A BRKR

Electrical & Grid-Support Datasheet

Power Center Max Hybrid 15 Electrical and Grid-Support Specifications
ManufacturerPower Center
Model Number (MPN)Max Hybrid 15
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)15.04 kW (15,040 W)
Nominal DC Input (Pdco)15,606 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
Listed Voltage Variants208V, 240V
CEC Weighted Efficiency96.5% (Class Estimate — Not listed in CEC)
MPPT Operating Window200 – 425 Vdc (NREL SAM Measured)
Max DC Input Voltage425 Vdc
Max DC Input Current48.8 A
Night Tare Loss21.2 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratorySGS
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for Max Hybrid 15
Max Continuous AC Current62.7 A @ 240V
125% Continuous Duty Current78.4 A
Minimum Standard Breaker80 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (16.54–20.3 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for Max Hybrid 15
Panel ClassRecommended QtyDC Array / Ratio
400W41–51 panels16.4–20.4 kW DC
440W38–46 panels16.7–20.2 kW DC
550W30–37 panels16.5–20.4 kW DC

Compatible Solar Panels for Power Center Max Hybrid 15

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Power Center Max Hybrid 15
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V6–7 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V6–7 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V6–7 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V6–7 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V6–7 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V5–5 per string (-10°C)Verify Pair

Engineering FAQ — Power Center Max Hybrid 15

What size circuit breaker does the Power Center Max Hybrid 15 require under NEC 705.12?
At 15.04 kW continuous AC output on 240V (62.7A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Center Max Hybrid 15?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 15.04 kW unit with 16.54 kW to 20.3 kW DC of solar modules without exceeding 425V cold Voc.

More Power Center Inverters

Essential Hybrid 5 (7.97 kW)Flex 10 (9.991 kW)Flex 12 (11.969 kW)D350-M1A-240A (0.346 kW)D350-M1 (0.349 kW)D400-M1A-240A (0.398 kW)All Power Center Equipment →