Power Electronics FP4200M (4198.71 kW)
4200 kW, 34500 Vac Grid Support Utility Interactive Central Battery Inverter with internal transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4198.71 kW
CEC Weighted Eff.
97.5%
MPPT / Max DC
934–1200V / 1200V
NEC 705.12 Breaker
90A @ 34500V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Electronics |
|---|---|
| Model Number (MPN) | FP4200M |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 4198.71 kW (4,198,710 W) |
| Nominal DC Input (Pdco) | 4,287,550 W |
| Nominal AC Voltage | 34500 Vac (3-Phase) |
| CEC Weighted Efficiency | 97.5% |
| MPPT Operating Window | 934 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 4018.3 A |
| Night Tare Loss | 7033 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 70.3 A @ 34500V |
|---|---|
| 125% Continuous Duty Current | 87.9 A |
| Minimum Standard Breaker | 90 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (4618.58–5668.26 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 11546–14171 panels | 4618.4–5668.4 kW DC |
| 440W | 10497–12882 panels | 4618.7–5668.1 kW DC |
| 550W | 8397–10306 panels | 4618.4–5668.3 kW DC |
CEC-Listed 240V Equivalents to Power Electronics FP4200M
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4198.71 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Power Electronics FP4200M
What size circuit breaker does the Power Electronics FP4200M require under NEC 705.12?
At 4198.71 kW continuous AC output on 34500V (70.3A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Electronics FP4200M?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4198.71 kW unit with 4618.58 kW to 5668.26 kW DC of solar modules without exceeding 1200V cold Voc.