Power Electronics FS4010K (4058.537 kW)
4010 kW, 630 Vac Grid Support Utility Interactive Inverter with Medium Voltage Transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
4058.537 kW
CEC Weighted Eff.
98%
MPPT / Max DC
891–1200V / 1200V
NEC 705.12 Breaker
4700A @ 630V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Electronics |
|---|---|
| Model Number (MPN) | FS4010K |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 4058.537 kW (4,058,537 W) |
| Nominal DC Input (Pdco) | 4,148,650 W |
| Nominal AC Voltage | 630 Vac (3-Phase) |
| CEC Weighted Efficiency | 98% |
| MPPT Operating Window | 891 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 3966.2 A |
| Night Tare Loss | 623.5 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 3719.5 A @ 630V |
|---|---|
| 125% Continuous Duty Current | 4649.4 A |
| Minimum Standard Breaker | 4700 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (4464.39–5479.02 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 11161–13698 panels | 4464.4–5479.2 kW DC |
| 440W | 10146–12452 panels | 4464.2–5478.9 kW DC |
| 550W | 8117–9962 panels | 4464.4–5479.1 kW DC |
CEC-Listed 240V Equivalents to Power Electronics FS4010K
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (4058.537 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Power Electronics FS4010K
What size circuit breaker does the Power Electronics FS4010K require under NEC 705.12?
At 4058.537 kW continuous AC output on 630V (3719.5A continuous), the 125% continuous duty rule requires a minimum 4700A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Power Electronics FS4010K?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 4058.537 kW unit with 4464.39 kW to 5479.02 kW DC of solar modules without exceeding 1200V cold Voc.