Power Electronics FS2000M (2178.068 kW)
2000 kW, 34 kV, Grid Support Utility Interactive Inverter with internal transformer. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
2178.068 kW
CEC Weighted Eff.
97%
MPPT / Max DC
849–1200V / 1200V
NEC 705.12 Breaker
50A @ 34500V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Power Electronics |
|---|---|
| Model Number (MPN) | FS2000M |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 2178.068 kW (2,178,068 W) |
| Nominal DC Input (Pdco) | 2,233,780 W |
| Nominal AC Voltage | 34500 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 849 – 1200 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1200 Vdc |
| Max DC Input Current | 2376.4 A |
| Night Tare Loss | 5970 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 36.5 A @ 34500V |
|---|---|
| 125% Continuous Duty Current | 45.6 A |
| Minimum Standard Breaker | 50 A |
| Busbar Requirement | 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11) |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (2395.87–2940.39 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 5990–7351 panels | 2396.0–2940.4 kW DC |
| 440W | 5445–6683 panels | 2395.8–2940.5 kW DC |
| 550W | 4356–5346 panels | 2395.8–2940.3 kW DC |
CEC-Listed 240V Equivalents to Power Electronics FS2000M
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (2178.068 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Engineering FAQ — Power Electronics FS2000M
What size circuit breaker does the Power Electronics FS2000M require under NEC 705.12?
At 2178.068 kW continuous AC output on 34500V (36.5A continuous), the 125% continuous duty rule requires a minimum 50A overcurrent breaker. Busbar note: 200A Busbar + 175A Main Derate OR Supply-Side Tap (NEC 705.11).
What solar array size pairs best with the Power Electronics FS2000M?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 2178.068 kW unit with 2395.87 kW to 2940.39 kW DC of solar modules without exceeding 1200V cold Voc.