Rhombus Energy Solutions BESI-50kW-480 (49.35 kW)
50kW, 480 Vac, transformer-less, 3-phase, Multi-Mode Grid Support Utility Interactive Energy Storage Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
49.35 kW
CEC Weighted Eff.
94%
MPPT / Max DC
550–840V / 840V
NEC 705.12 Breaker
80A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Rhombus Energy Solutions |
|---|---|
| Model Number (MPN) | BESI-50kW-480 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 49.35 kW (49,350 W) |
| Nominal DC Input (Pdco) | 51,401 W |
| Nominal AC Voltage | 480 Vac (3-Phase) |
| CEC Weighted Efficiency | 94% |
| MPPT Operating Window | 550 – 840 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 840 Vdc |
| Max DC Input Current | 80.8 A |
| Night Tare Loss | 103 W |
| UL 1741 Supplement SB | No / Non-US |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Not listed in CEC |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 59.4 A @ 480V |
|---|---|
| 125% Continuous Duty Current | 74.3 A |
| Minimum Standard Breaker | 80 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (54.29–66.62 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 136–167 panels | 54.4–66.8 kW DC |
| 440W | 123–151 panels | 54.1–66.4 kW DC |
| 550W | 99–121 panels | 54.5–66.5 kW DC |
CEC-Listed 240V Equivalents to Rhombus Energy Solutions BESI-50kW-480
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (49.35 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Rhombus Energy Solutions BESI-50kW-480
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-545-BTC-BG | 545 W | 48.2 V | 16–16 per string (-10°C) | Verify Pair |
| Trina Solar TSM-460NEG9RH.25 | 460 W | 36.3 V | 21–21 per string (-10°C) | Verify Pair |
| Mission Solar MSX10-445HN0B {C} | 445 W | 38.7 V | 20–20 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.TRON BLK M-G2.D+ 415 | 415 W | 38.47 V | 20–20 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 16–16 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 21–22 per string (-10°C) | Verify Pair |
Engineering FAQ — Rhombus Energy Solutions BESI-50kW-480
What size circuit breaker does the Rhombus Energy Solutions BESI-50kW-480 require under NEC 705.12?
At 49.35 kW continuous AC output on 480V (59.4A continuous), the 125% continuous duty rule requires a minimum 80A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Rhombus Energy Solutions BESI-50kW-480?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 49.35 kW unit with 54.29 kW to 66.62 kW DC of solar modules without exceeding 840V cold Voc.