RE CEC-Listed · Commercial / C&ICommercial 3-PhaseBattery Hybrid

Rhombus Energy Solutions RES-BESS60DP-480 (59.789 kW)

60 kW, 480 Vac Grid Support Utility Interactive PV and Battery Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
59.789 kW
CEC Weighted Eff.
91.5%
MPPT / Max DC
270–870V / 870V
NEC 705.12 Breaker
90A @ 480V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Rhombus Energy Solutions RES-BESS60DP-480 — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 270–870 Vdc 270V 870V MAX 870V PV DC INPUT ≤ 870V DC 59.789 kW · 91.5% CEC PV + BATTERY HYBRID AC OUTPUT 480V · 90A BRKR

Electrical & Grid-Support Datasheet

Rhombus Energy Solutions RES-BESS60DP-480 Electrical and Grid-Support Specifications
ManufacturerRhombus Energy Solutions
Model Number (MPN)RES-BESS60DP-480
Inverter TopologyCommercial 3-Phase Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)59.789 kW (59,789 W)
Nominal DC Input (Pdco)64,196 W
Nominal AC Voltage480 Vac (3-Phase)
CEC Weighted Efficiency91.5%
MPPT Operating Window270 – 870 Vdc (NREL SAM Measured)
Max DC Input Voltage870 Vdc
Max DC Input Current145.6 A
Night Tare Loss92 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterYes

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for RES-BESS60DP-480
Max Continuous AC Current71.9 A @ 480V
125% Continuous Duty Current89.9 A
Minimum Standard Breaker90 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (65.77–80.72 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for RES-BESS60DP-480
Panel ClassRecommended QtyDC Array / Ratio
400W164–202 panels65.6–80.8 kW DC
440W149–183 panels65.6–80.5 kW DC
550W120–147 panels66.0–80.8 kW DC

CEC-Listed 240V Equivalents to Rhombus Energy Solutions RES-BESS60DP-480

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (59.789 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Compatible Solar Panels for Rhombus Energy Solutions RES-BESS60DP-480

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Rhombus Energy Solutions RES-BESS60DP-480
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–15 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–15 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–14 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–15 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–16 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–12 per string (-10°C)Verify Pair

Engineering FAQ — Rhombus Energy Solutions RES-BESS60DP-480

What size circuit breaker does the Rhombus Energy Solutions RES-BESS60DP-480 require under NEC 705.12?
At 59.789 kW continuous AC output on 480V (71.9A continuous), the 125% continuous duty rule requires a minimum 90A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Rhombus Energy Solutions RES-BESS60DP-480?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 59.789 kW unit with 65.77 kW to 80.72 kW DC of solar modules without exceeding 870V cold Voc.

More Rhombus Energy Solutions Inverters

BESI-50kW-480 (49.35 kW)BESS-50kW-480 (49.35 kW)All Rhombus Energy Solutions Equipment →