Schneider Electric official logoCEC-Listed · Commercial / C&ICommercial 3-Phase

Schneider Electric CS1800-NA (1800 kW)

1.8 MW, 1500 Vdc, 575 Vac, 3-phase, Special Purpose Grid Support Utility Interactive PV Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
1800 kW
CEC Weighted Eff.
98%
MPPT / Max DC
856–1200V / 1200V
NEC 705.12 Breaker
2300A @ 575V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Schneider Electric CS1800-NA — Illustrative category photo — not this exact model · Real commercial solar inverter installation
Illustrative category photo — not this exact model · Real commercial solar inverter installationWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (STRING) MPPT 856–1200 Vdc 856V 1200V MAX 1200V PV DC INPUT ≤ 1200V DC 1800 kW · 98% CEC GRID-SUPPORT INVERTER AC OUTPUT 575V · 2300A BRKR

Electrical & Grid-Support Datasheet

Schneider Electric CS1800-NA Electrical and Grid-Support Specifications
ManufacturerSchneider Electric
Model Number (MPN)CS1800-NA
Inverter TopologyCommercial 3-Phase Inverter
Continuous AC Power (Paco)1800 kW (1,800,000 W)
Nominal DC Input (Pdco)1,847,460 W
Nominal AC Voltage575 Vac (3-Phase)
CEC Weighted Efficiency98%
MPPT Operating Window856 – 1200 Vdc (NREL SAM Measured)
Max DC Input Voltage1200 Vdc
Max DC Input Current1804.2 A
Night Tare Loss295 W
UL 1741 Supplement SBNo / Non-US
UL 1741 Supplement SACertified
Certifying LaboratoryNot listed in CEC
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for CS1800-NA
Max Continuous AC Current1807.4 A @ 575V
125% Continuous Duty Current2259.3 A
Minimum Standard Breaker2300 A
Busbar RequirementSupply-Side Tap (NEC 705.11) or 400A/Commercial Service

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1980–2430 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for CS1800-NA
Panel ClassRecommended QtyDC Array / Ratio
400W4950–6075 panels1980.0–2430.0 kW DC
440W4500–5523 panels1980.0–2430.1 kW DC
550W3600–4418 panels1980.0–2429.9 kW DC

CEC-Listed 240V Equivalents to Schneider Electric CS1800-NA

Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (1800 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:

CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid

Isuna U20K-PH

CEC Efficiency: 97%
Datasheet →
CEC-Listed · 240V19.378 kW
Base Power · Hybrid

000599.XX.Y

CEC Efficiency: 96%
Datasheet →
CEC-Listed · 240V17.944 kW
SRNE Solar · Hybrid

HEBP48180U380-H

CEC Efficiency: 96.5%
Datasheet →

Engineering FAQ — Schneider Electric CS1800-NA

What size circuit breaker does the Schneider Electric CS1800-NA require under NEC 705.12?
At 1800 kW continuous AC output on 575V (1807.4A continuous), the 125% continuous duty rule requires a minimum 2300A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Schneider Electric CS1800-NA?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 1800 kW unit with 1980 kW to 2430 kW DC of solar modules without exceeding 1200V cold Voc.

More Schneider Electric Inverters

XW Pro 6848 NA (6.019 kW)HY8K1NA1 (7.626 kW)All Schneider Electric Equipment →