Schneider Electric EMGPCS0500ACCANS00 (502.611 kW)
500 kW, 400 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
502.611 kW
CEC Weighted Eff.
97%
MPPT / Max DC
600–900V / 900V
NEC 705.12 Breaker
1000A @ 400V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Schneider Electric |
|---|---|
| Model Number (MPN) | EMGPCS0500ACCANS00 |
| Inverter Topology | Commercial 3-Phase Inverter (PV + Battery Hybrid) |
| Continuous AC Power (Paco) | 502.611 kW (502,611 W) |
| Nominal DC Input (Pdco) | 515,924 W |
| Nominal AC Voltage | 400 Vac (3-Phase) |
| CEC Weighted Efficiency | 97% |
| MPPT Operating Window | 600 – 900 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 900 Vdc |
| Max DC Input Current | 687.9 A |
| Night Tare Loss | 335.38 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | No |
| Certifying Laboratory | Intertek |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 725.5 A @ 400V |
|---|---|
| 125% Continuous Duty Current | 906.9 A |
| Minimum Standard Breaker | 1000 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (552.87–678.52 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 1382–1696 panels | 552.8–678.4 kW DC |
| 440W | 1257–1542 panels | 553.1–678.5 kW DC |
| 550W | 1005–1234 panels | 552.8–678.7 kW DC |
CEC-Listed 240V Equivalents to Schneider Electric EMGPCS0500ACCANS00
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (502.611 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Schneider Electric EMGPCS0500ACCANS00
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 16–16 per string (-10°C) | Verify Pair |
| Silfab Solar SIL-540XM | 540 W | 47.95 V | 17–17 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 23–23 per string (-10°C) | Verify Pair |
| REC Solar REC400AA Pure 2 | 400 W | 48.5 V | 17–17 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM | 435 W | 81.4 V | 10–10 per string (-10°C) | Verify Pair |
Engineering FAQ — Schneider Electric EMGPCS0500ACCANS00
What size circuit breaker does the Schneider Electric EMGPCS0500ACCANS00 require under NEC 705.12?
At 502.611 kW continuous AC output on 400V (725.5A continuous), the 125% continuous duty rule requires a minimum 1000A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Schneider Electric EMGPCS0500ACCANS00?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 502.611 kW unit with 552.87 kW to 678.52 kW DC of solar modules without exceeding 900V cold Voc.