Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0 (136.47 kW)
137 kVA, 600 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
136.47 kW
CEC Weighted Eff.
99%
MPPT / Max DC
875–1300V / 1300V
NEC 705.12 Breaker
175A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Siemens Industry |
|---|---|
| Model Number (MPN) | blueplanet125 TL3 GEN2 M1 WM OD USP0 |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 136.47 kW (136,470 W) |
| Nominal DC Input (Pdco) | 138,301 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 99% |
| MPPT Operating Window | 875 – 1300 Vdc (NREL SAM Measured) |
| Max DC Input Voltage | 1300 Vdc |
| Max DC Input Current | 138.3 A |
| Night Tare Loss | 5.27 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Bureau Veritas Consumer Products Services |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 131.3 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 164.1 A |
| Minimum Standard Breaker | 175 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (150.12–184.23 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 375–461 panels | 150.0–184.4 kW DC |
| 440W | 341–419 panels | 150.0–184.4 kW DC |
| 550W | 273–335 panels | 150.2–184.3 kW DC |
CEC-Listed 240V Equivalents to Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (136.47 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0
Test any of 3,007 panels with this inverter →| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 23–23 per string (-10°C) | Verify Pair |
| SEG Solar SEG-510-BTB-HV | 510 W | 44.38 V | 27–27 per string (-10°C) | Verify Pair |
| Canadian Solar CS6.2-48TM-460H | 460 W | 36.2 V | 33–34 per string (-10°C) | Verify Pair |
| REC Solar REC450AA 72 | 450 W | 53.2 V | 22–22 per string (-10°C) | Verify Pair |
| Maxeon / SunPower SPR-MAX3-435-COM-R | 435 W | 40.7 V | 29–29 per string (-10°C) | Verify Pair |
Engineering FAQ — Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0
What size circuit breaker does the Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0 require under NEC 705.12?
At 136.47 kW continuous AC output on 600V (131.3A continuous), the 125% continuous duty rule requires a minimum 175A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Siemens Industry blueplanet125 TL3 GEN2 M1 WM OD USP0?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 136.47 kW unit with 150.12 kW to 184.23 kW DC of solar modules without exceeding 1300V cold Voc.