CEC-Listed · Commercial / C&ICommercial 3-PhaseUL 1741-SB (3rd Ed.)Estimated MPPT — Verify Manufacturer Datasheet
Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX (155.917 kW)
155 kVA, 600 Vac, Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .
Continuous AC Output
155.917 kW
CEC Weighted Eff.
98.5%
MPPT / Max DC
250–850V / 1000VEstimated MPPT — Verify Datasheet
NEC 705.12 Breaker
200A @ 600V
Inverter Engineering Tools
CEC-Listed · Commercial / C&I: Commercial / legacy unit — see US residential split-phase equivalents below.
View US 240V Equivalents →Run String Voltage Check →
Electrical & Grid-Support Datasheet
| Manufacturer | Siemens Industry |
|---|---|
| Model Number (MPN) | blueplanet155 TL3 GEN2 M1 WM OD USPX |
| Inverter Topology | Commercial 3-Phase Inverter |
| Continuous AC Power (Paco) | 155.917 kW (155,917 W) |
| Nominal DC Input (Pdco) | 158,291 W |
| Nominal AC Voltage | 600 Vac (3-Phase) |
| CEC Weighted Efficiency | 98.5% |
| MPPT Operating Window | 250 – 850 Vdc (Nominal Class Estimate (Verify Datasheet))Estimated MPPT — Verify Manufacturer Datasheet before string design |
| Max DC Input Voltage | 1000 Vdc |
| Max DC Input Current | 298.8 A |
| Night Tare Loss | 5.27 W |
| UL 1741 Supplement SB | Certified (3rd Ed.) |
| UL 1741 Supplement SA | Certified |
| Certifying Laboratory | Bureau Veritas Consumer Products Services |
| Built-in Revenue Meter | No / Optional |
NEC 705.12(B) Backfeed & Panel Check
| Max Continuous AC Current | 150 A @ 600V |
|---|---|
| 125% Continuous Duty Current | 187.5 A |
| Minimum Standard Breaker | 200 A |
| Busbar Requirement | Supply-Side Tap (NEC 705.11) or 400A/Commercial Service |
Recommended PV Array Pairing
Target DC/AC ratio 1.10×–1.35× (171.51–210.49 kW DC total).
| Panel Class | Recommended Qty | DC Array / Ratio |
|---|---|---|
| 400W | 429–526 panels | 171.6–210.4 kW DC |
| 440W | 390–478 panels | 171.6–210.3 kW DC |
| 550W | 312–383 panels | 171.6–210.7 kW DC |
CEC-Listed 240V Equivalents to Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX
Installing in the United States? These UL 1741-SB / 240V split-phase inverters match this class (155.917 kW Commercial 3-Phase Inverter) and can be added directly to your US System Kit:
CEC-Listed · 240V20.181 kW
Shenzhen Sinexcel Isuna Energy Technology · Hybrid
Isuna U20K-PH
CEC Efficiency: 97%
Compatible Solar Panels for Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX
Test any of 3,007 panels with this inverter →Estimated MPPT — Verify Manufacturer DatasheetThis inverter’s MPPT window (250–850 Vdc) is a topology estimate because the CEC file did not list explicit MPPT bounds. Confirm exact startup and MPPT voltage limits on the manufacturer datasheet before finalizing string lengths.
| Solar Panel Model | STC Power | Voc (25°C) | String / Pairing Fit | Action |
|---|---|---|---|---|
| Boviet Solar BVM7612M-580-H-HC-BF | 580 W | 52.42 V | 7–17 per string (-10°C) | Verify Pair |
| SEG Solar SEG-580-BTA-HV | 580 W | 51.95 V | 7–17 per string (-10°C) | Verify Pair |
| Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575 | 575 W | 53.5 V | 7–17 per string (-10°C) | Verify Pair |
| Mission Solar MSH10-560HN4G {A} | 560 W | 50.5 V | 7–18 per string (-10°C) | Verify Pair |
| Canadian Solar CS6W-555MB-AG | 555 W | 49.8 V | 7–18 per string (-10°C) | Verify Pair |
| REC Solar REC475AA Pure-RX-DC | 475 W | 65.7 V | 6–14 per string (-10°C) | Verify Pair |
Engineering FAQ — Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX
What size circuit breaker does the Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX require under NEC 705.12?
At 155.917 kW continuous AC output on 600V (150A continuous), the 125% continuous duty rule requires a minimum 200A overcurrent breaker. Busbar note: Supply-Side Tap (NEC 705.11) or 400A/Commercial Service.
What solar array size pairs best with the Siemens Industry blueplanet155 TL3 GEN2 M1 WM OD USPX?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 155.917 kW unit with 171.51 kW to 210.49 kW DC of solar modules without exceeding 1000V cold Voc.