SI CEC-Listed · 240V ResidentialMicroinverterUL 1741-SB (3rd Ed.)

Sigenergy SigenMicro 960 US (0.969 kW)

0.96 kW, 240 Vac Grid Support Utility Interactive Microinverter with PCS functionality. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
0.969 kW
CEC Weighted Eff.
97%
MPPT / Max DC
35–55V / 55V
NEC 705.12 Breaker
15A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sigenergy SigenMicro 960 US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (MICROINVERTER) MPPT 35–55 Vdc 35V 55V MAX 55V PV DC INPUT ≤ 55V DC 0.969 kW · 97% CEC GRID-SUPPORT INVERTER AC OUTPUT 240V · 15A BRKR

Electrical & Grid-Support Datasheet

Sigenergy SigenMicro 960 US Electrical and Grid-Support Specifications
ManufacturerSigenergy
Model Number (MPN)SigenMicro 960 US
Inverter TopologyMicroinverter
Continuous AC Power (Paco)0.969 kW (969 W)
Nominal DC Input (Pdco)1,014 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window35 – 55 Vdc (NREL SAM Measured)
Max DC Input Voltage55 Vdc
Max DC Input Current22.5 A
Night Tare Loss0.04 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SigenMicro 960 US
Max Continuous AC Current4 A @ 240V
125% Continuous Duty Current5.0 A
Minimum Standard Breaker15 A
Busbar Requirement100A Busbar (120% rule: up to 20A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (1.07–1.31 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SigenMicro 960 US
Panel ClassRecommended QtyDC Array / Ratio
400W1 panel1:1 pairing (0.41× DC/AC)
440W1 panel1:1 pairing (0.45× DC/AC)
550W1 panel1:1 pairing (0.57× DC/AC)

Engineering FAQ — Sigenergy SigenMicro 960 US

What size circuit breaker does the Sigenergy SigenMicro 960 US require under NEC 705.12?
At 0.969 kW continuous AC output on 240V (4A continuous), the 125% continuous duty rule requires a minimum 15A overcurrent breaker. Busbar note: 100A Busbar (120% rule: up to 20A backfeed).
What solar array size pairs best with the Sigenergy SigenMicro 960 US?
As a 969W microinverter, it pairs 1:1 with panels rated roughly 1017W to 1405W STC.

More Sigenergy Inverters

SigenMicro 384 US (0.388 kW)SigenMicro 480 US (0.484 kW)SigenMicro 768 US (0.776 kW)SigenStor EC 4.8 SP US (4.808 kW)SigenStor EC 5.7 SP US (5.776 kW)SigenStor EC 7.6 SP US (7.649 kW)All Sigenergy Equipment →