SI CEC-Listed · 240V ResidentialHybridUL 1741-SB (3rd Ed.)Battery Hybrid

Sigenergy SigenStor EC 5.7 SP US (5.776 kW)

5.7 kW, 240 Vac Grid Support Utility Interactive Inverter. Registry source: CEC Grid-Support Inverter List (Nov 2026) · CEC listing date: · Registry snapshot: .

Continuous AC Output
5.776 kW
CEC Weighted Eff.
97%
MPPT / Max DC
270–480V / 480V
NEC 705.12 Breaker
35A @ 240V
Inverter Engineering Tools
Test String Sizing With Panels →
Sigenergy SigenStor EC 5.7 SP US — Illustrative category photo — not this exact model · Real residential hybrid/string solar inverter
Illustrative category photo — not this exact model · Real residential hybrid/string solar inverterWikimedia Commons — File:Central inverter cutout.jpg (CC0)
DC INPUT & MPPT TRACKING WINDOW (HYBRID) MPPT 270–480 Vdc 270V 480V MAX 480V PV DC INPUT ≤ 480V DC 5.776 kW · 97% CEC PV + BATTERY HYBRID AC OUTPUT 240V · 35A BRKR

Electrical & Grid-Support Datasheet

Sigenergy SigenStor EC 5.7 SP US Electrical and Grid-Support Specifications
ManufacturerSigenergy
Model Number (MPN)SigenStor EC 5.7 SP US
Inverter TopologyHybrid Inverter (PV + Battery Hybrid)
Continuous AC Power (Paco)5.776 kW (5,776 W)
Nominal DC Input (Pdco)5,950 W
Nominal AC Voltage240 Vac (Split/Single-Phase)
CEC Weighted Efficiency97%
MPPT Operating Window270 – 480 Vdc (NREL SAM Measured)
Max DC Input Voltage480 Vdc
Max DC Input Current16.5 A
Night Tare Loss3.3 W
UL 1741 Supplement SBCertified (3rd Ed.)
UL 1741 Supplement SANo
Certifying LaboratoryCSA Group
Built-in Revenue MeterNo / Optional

NEC 705.12(B) Backfeed & Panel Check

NEC 705.12 Backfeed Breaker Calculation for SigenStor EC 5.7 SP US
Max Continuous AC Current24.1 A @ 240V
125% Continuous Duty Current30.1 A
Minimum Standard Breaker35 A
Busbar Requirement200A Busbar (120% rule: up to 40A backfeed)

Recommended PV Array Pairing

Target DC/AC ratio 1.10×–1.35× (6.35–7.8 kW DC total).

Recommended Solar Panel Quantity by Wattage Class for SigenStor EC 5.7 SP US
Panel ClassRecommended QtyDC Array / Ratio
400W16–20 panels6.4–8.0 kW DC
440W14–18 panels6.2–7.9 kW DC
550W12–14 panels6.6–7.7 kW DC

Compatible Solar Panels for Sigenergy SigenStor EC 5.7 SP US

Test any of 3,007 panels with this inverter →
Compatible Solar Panels for Sigenergy SigenStor EC 5.7 SP US
Solar Panel ModelSTC PowerVoc (25°C)String / Pairing FitAction
Boviet Solar BVM7612M-580-H-HC-BF580 W52.42 V8–8 per string (-10°C)Verify Pair
SEG Solar SEG-580-BTA-HV580 W51.95 V8–8 per string (-10°C)Verify Pair
Qcells (Hanwha) Q.PEAK DUO XL-G11S.B3/BFG 575575 W53.5 V8–8 per string (-10°C)Verify Pair
Mission Solar MSH10-560HN4G {A}560 W50.5 V8–8 per string (-10°C)Verify Pair
Canadian Solar CS6W-555MB-AG555 W49.8 V8–8 per string (-10°C)Verify Pair
REC Solar REC475AA Pure-RX-DC475 W65.7 V6–6 per string (-10°C)Verify Pair

Engineering FAQ — Sigenergy SigenStor EC 5.7 SP US

What size circuit breaker does the Sigenergy SigenStor EC 5.7 SP US require under NEC 705.12?
At 5.776 kW continuous AC output on 240V (24.1A continuous), the 125% continuous duty rule requires a minimum 35A overcurrent breaker. Busbar note: 200A Busbar (120% rule: up to 40A backfeed).
What solar array size pairs best with the Sigenergy SigenStor EC 5.7 SP US?
For balanced annual yield (1.10× to 1.35× DC/AC ratio), pair this 5.776 kW unit with 6.35 kW to 7.8 kW DC of solar modules without exceeding 480V cold Voc.

More Sigenergy Inverters

SigenMicro 768 US (0.776 kW)SigenMicro 960 US (0.969 kW)SigenStor EC 4.8 SP US (4.808 kW)SigenStor EC 7.6 SP US (7.649 kW)SigenStor EC 9.6 SP US (9.653 kW)SigenStor EC SP US (11.503 kW)All Sigenergy Equipment →